HomeYour location:Homelow-voltage electrical apparatusrelayintermediate relay → JXT series universal relay (JXT type)
Column tabs 
Product name: JXT series universal relay (JXT type)
specification: JXT series universal relay (JXT type)
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- intermediate relay
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


JXT series universal relay (JXT type)Detailed product description:Column tabs
Application of DZ-6 series universal relay (JXT type)
DZ-6 (JXT) series universal relays are used in various automatic control devices, program control, and communication equipment for switching AC and DC circuits.

2 Working principle and structure
2.1 The relay is a small electromagnetic relay. When the coil is energized, the armature attracts, the dynamic contact closes, and the dynamic contact opens. When the coil loses power, the armature resets, the dynamic contact opens, and the dynamic contact closes.
2.2 There are three types of structures
2.2.1 Type F is a plug-in socket that is welded onto the board.
2.2.2 Type B is a plug-in type, which is connected to the socket with screws before the board is installed.
2.2.3 Type C is suitable for printed circuit board terminal type, without a cover.
2.3 The external dimension diagram, installation opening diagram, and internal wiring diagram are shown in the figure.

DZ-6 series universal relay (JXT type) appearance and installation dimensions

Left is DZ-6B 3Z, right is DZ-6B 2Z (plug-in board front screw connection socket)
DZ-6 series universal relay (JXT type) external dimensions 1

Left is DZ-6B 3Z, right is DZ-6B 2Z (plug-in board with front screw connection to rail socket)

DZ-6 series universal relay (JXT type) external dimensions 2
DZ-6C
DZ-6 series universal relay (JXT type) external dimensions 3
DZ-6F 3Z

DZ-6 series universal relay (JXT type) external dimensions 4
DZ-6F 2Z

DZ-6 series universal relay (JXT type) opening size
Figure 2 shows the installation opening diagram for DZ-6F 3Z, DZ-6F 2Z, DZ-6B 2Z, and DZ-6C
DZ-6 series universal relay (JXT type) contact diagram
DZ-6F 2Z
DZ-6B 2Z
DZ-6F 3Z
DZ-6B 3Z
DZ-6F 2ZA
DZ-6B 2ZA
DZ-6F 3ZA
DZ-6B 3ZA
DZ-6F 3ZB
DZ-6B 3ZB
Figure 3 Internal wiring diagram

3 Model specifications: see Table 1

DZ-6 series universal relay (JXT type) model description
*Note: The terminal arrangement represented by codes A and B is shown in Figure 3, and unmarked codes refer to conventional arrangements.

3.2 Model specifications (see Table 1)

model

contact form

rated voltage

DC(V)

AC(V)

DZ-6F2Z
DZ-6F2ZA

2-pay conversion

6,12,24,

48,110,220

6,12,24,

36,110,127,

220,380

DZ-6F3Z
DZ-6F3ZA
DZ-6F3ZB

3 Payment Conversion

DZ-6B2Z
DZ-6B2ZA

2-pay conversion

DZ-6B3Z
DZ-6B3ZA
DZ-6B3ZB

3 Payment Conversion

DZ-6C2Z
DZ-6C3Z

2-pay conversion
3 Payment Conversion


Technical data of DZ-6 series universal relay (JXT type)
4.1 Operating voltage: AC type not exceeding 85% of rated voltage;
The DC type shall not exceed 80% of the rated voltage.
4.2 Return voltage: AC type not exceeding 15% of rated voltage;
The DC type shall not exceed 10% of the rated voltage.
4.3 Action time: not exceeding 20ms.
4.4 Contact Capacity: See Table 2-3.
Table 2 Contact breaking capacity

Load performance

Resistive load cos&=1

Inductive load cos&=0.4 L/R=5ms

Coil power consumption

Current value (A)

Voltage value (V)

AC.2.5VA

DC.1.5W

DC.1W

AC.2.5VA

DC.1.5W

DC.1W

AC

two hundred and twenty

three

two

one

zero point seven

three hundred and eighty

one point two

zero point eight

zero point four

zero point two eight

DC

six

three

two

one point five

one

twelve

two point seven

one point eight

one

zero point seven

twenty-four

one point eight

one point two

zero point five

zero point one eight

two hundred and twenty

zero point two

zero point one five

-

-


Table 3 Maximum breaking capacity of contacts

Load performance

Resistive load cos&=1

Inductive load cos&=0.4 L/R=5ms

Coil power consumption

Current value (A)

Voltage value (V)

AC.2.5VA

DC.1.5W

DC.1W

AC.2.5VA

DC.1.5W

DC.1W

AC

two hundred and twenty

seven point five

five

three

two

three hundred and eighty

three

two

one

zero point seven

DC

six

ten

five

seven

four point six

twelve

ten

four point six

five

four point three

twenty-four

ten

three

three

two point four

two hundred and twenty

zero point three

zero point three

zero point one

zero point zero five


4.5 Electrical lifespan: 105 times at the maximum breaking capacity of the contact; At the rated breaking capacity of the contact point, 5 × 105 times.
4.6 Dielectric strength: Between the conductive and non-conductive parts of the relay, as well as between the coil circuit and the contact circuit, it can withstand an AC of 50Hz, a voltage of 2 kV, and a test duration of 1 minute without breakdown or flashover.

5 Ordering Instructions
Please specify when placing an order
5.1 The name and model of the relay are not specified, and A and B are supplied in accordance with the conventional wiring terminal arrangement;
5.2 Rated parameters;
5.3 Order quantity;
5.4 Delivery method.

JXT series universal relay (JXT type)
  • Related product tags  Related Products:
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference