Structure and purpose:
The LXW10 (831600) series micro switch has electrically inseparable adjacent contact elements, suitable for use in electrical systems with AC 50Hz, maximum operating voltage of 380V, and DC voltage up to 220V for stroke detection, protection, and interlocking. It is also suitable for household and similar industrial appliances..
Standard:
Compliant with standards such as GB/T14048.1 and GB14048.5
The structural characteristics and operating principle of the switch:
The LXW10 (831600) microswitch is a momentary single break electrical component that uses a normally closed contact, a normally open contact, and a common jumping elastic contact piece supported on a metal bracket as the moving contact.
When the switch is subjected to external forces (such as impact blocks) and the contact piece is compressed beyond the dead point through the operating element, even if the normally closed and normally open contacts are instantly switched, when the external force decreases to a certain value (less than the reset force), the contacts will immediately automatically reset to their original state.
Classification:
1. Classified by structural type:
a) Push rod plunger type;
b) Hinge lever type;
c) Short lever type hinge roller;
d) Hinge roller lever type;
e) Panel installation plunger type.
2. Divided by wiring form
a) Welding type;
b) Plug in type.
Use categories and basic parameters:
1. Use category
The usage categories of switches are shown in Table 1:
|
Type of electric current |
Usage category |
typical use |
|
communication |
AC—15 |
Control the load of the AC electromagnet |
|
direct current |
DC—13 |
Control the load of DC electromagnet |
2. Basic parameters of LXW10 (831600) series micro switch
The basic parameters of the switch are shown in Table 2:
|
Rated working voltage V |
Rated insulation voltage V |
Rated control capacity |
Agreed heating current A |
Number of contacts |
|
Normally Open |
normally closed |
|
communication |
three hundred and eighty |
three hundred and eighty |
100VA |
ten |
one |
one |
|
direct current |
two hundred and twenty |
44W |
Type spectrum:

Electrical and mechanical lifespan of switches:
The AC lifespan of the switch is 600000 times;
2. The DC life of the switch is 300000 times;
3. The mechanical lifespan of the switch is 3 million cycles.