HomeYour location:Homelow-voltage electrical apparatuslow-voltage circuit breakerMiniature Circuit Breaker → M-L7 series high breaking miniature circuit breaker
Column tabs 
Product name: M-L7 series high breaking miniature circuit breaker
specification: M-L7 series high breaking miniature circuit breaker
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Miniature Circuit Breaker
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


M-L7 series high breaking miniature circuit breakerDetailed product description:Column tabs

Technical parameters of M-L7 series high breaking miniature circuit breaker
Electrical parameters
a. Compliant with electrical standards: EN0898 (IEC898)
GB10963
b. Rated voltage (Ue): 230/400V; 50/60Hz
c. Rated breaking capacity Icu: 10kA IEC898 (1-63A)
d. DC short-circuit breaking capacity: maximum 48V (M-L7..., 10kA) single pole
Maximum 250V (M-L7-DC, 6kA) unipolar
e. Release characteristics: B, C, D characteristic curves
f. Maximum side fuse: 100A gL (>10kA)
g. Selective level: 3
h. Working environment temperature: -5 to+40oC
i. Shell protection level: IP40 (after installation)
j. Lifespan: Electrical, no less than 8000 on-off actions
Mechanical, with no less than 20000 on-off actions
mechanical parameters
a. Exposed surface length: 45mm
b. Shell height: 80mm
c. Shell width: 17.5mm per pole (single pole)
d. Installation method: Using IEC standard guide rail 35mm
e. Terminal form: Dual purpose terminal can connect busbar and wire
F. Terminal wiring capacity: busbar 1-25mm2; Bus thickness 0.8-2mm

Overall dimensions
Installation dimensions of M-L7 series high breaking miniature circuit breaker

Unless otherwise stated, a two pole switch is two modules wide, and a four pole switch is four modules wide.

It provides protection against overload and short circuit of electrical circuits or equipment, and has power isolation function. M-L7 series high breaking miniature circuit breaker 1P
1 PoleM-L7 series high breaking miniature circuit breaker 1P contact
M-L7 series high breaking miniature circuit breaker 2P
2-poleM-L7 series high breaking miniature circuit breaker 2P contact
M-L7 series high breaking miniature circuit breaker 3P
3 polesM-L7 series high breaking miniature circuit breaker 3P contact
M-L7 series high breaking miniature circuit breaker 4P
4-poleM-L7 series high breaking miniature circuit breaker 4P contact
Rated current In (A) model model model model
C characteristic curve
Instantaneous release 5-10 in
Mainly applicable to lighting or partial power circuits
one M-L7-1/1/C M-L7-1/2/C M-L7-1/3/C M-L7-1/4/C
two M-L7-2/1/C M-L7-2/2/C M-L7-2/3/C M-L7-2/4/C
three M-L7-3/1/C M-L7-3/2/C M-L7-3/3/C M-L7-3/4/C
four M-L7-4/1/C M-L7-4/2/C M-L7-4/3/C M-L7-4/4/C
six M-L7-6/1/C M-L7-6/2/C M-L7-6/3/C M-L7-6/4/C
ten M-L7-10/1/C M-L7-10/2/C M-L7-10/3/C M-L7-10/4/C
sixteen M-L7-16/1/C M-L7-16/2/C M-L7-16/3/C M-L7-16/4/C
twenty M-L7-20/1/C M-L7-20/2/C M-L7-20/3/C M-L7-20/4/C
twenty-five M-L7-25/1/C M-L7-25/2/C M-L7-25/3/C M-L7-25/4/C
thirty-two M-L7-32/1/C M-L7-32/2/C M-L7-32/3/C M-L7-32/4/C
forty M-L7-40/1/C M-L7-40/2/C M-L7-40/3/C M-L7-40/4/C
fifty M-L7-50/1/C M-L7-50/2/C M-L7-50/3/C M-L7-50/4/C
sixty-three M-L7-63/1/C M-L7-63/2/C M-L7-63/3/C M-L7-63/4/C
D characteristic curve
Instantaneous release of 10~15In
Mainly applicable to power circuits or other strongly inductive circuits
two M-L7-2/1/C M-L7-2/2/C M-L7-2/3/C M-L7-2/4/C
four M-L7-4/1/D M-L7-4/2/D M-L7-4/3/D M-L7-4/4/D
six M-L7-6/1/D M-L7-6/2/D M-L7-6/3/D M-L7-6/4/D
ten M-L7-10/1/D M-L7-10/2/D M-L7-10/3/D M-L7-10/4/D
sixteen M-L7-16/1/D M-L7-16/2/D M-L7-16/3/D M-L7-16/4/D
twenty M-L7-20/1/D M-L7-20/2/D M-L7-20/3/D M-L7-20/4/D
twenty-five M-L7-25/1/D M-L7-25/2/D M-L7-25/3/D M-L7-25/4/D
thirty-two M-L7-32/1/D M-L7-32/2/D M-L7-32/3/D M-L7-32/4/D
forty M-L7-40/1/D M-L7-40/2/D M-L7-40/3/D M-L7-40/4/D
fifty M-L7-50/1/D M-L7-50/2/D M-L7-50/3/D M-L7-50/4/D
sixty-three M-L7-63/1/D M-L7-63/2/D M-L7-63/3/D M-L7-63/4/D


Product Features
Compliant with the latest standards IEC898 and GB10963;
Accurate setting of current trip;
The breaking capacity can reach up to 10kA;
Extremely high current limiting capability, capable of achieving high selectivity;
Double terminals on both sides are suitable for busbar and single core wires;
Bus bars can be used on both sides;
Multi functional accessory series;
The wiring screws of the composite slot have high torque, secure wiring, and can achieve fast wiring;
The incoming direction of the power supply is arbitrary;
Having DC products, it can be widely used in fields such as telecommunications or electric locomotives.

Scope of application:

Suitable for overload and short circuit protection of DC lines. Especially suitable for industries such as communication, power, and locomotives. M-L7 series high breaking miniature circuit breaker 1PM-L7 series high breaking miniature circuit breaker 1P application contact M-L7 series high breaking miniature circuit breaker 2PM-L7 series high breaking miniature circuit breaker 2P application contact
Rated current (A) In model model
The rated breaking capacity is:
M-L7 series high breaking miniature circuit breaker breaking capacity
C characteristic curve
Instantaneous release 5-10In

Note: The positive and negative poles of the power supply must not be connected incorrectly, otherwise the fault current cannot be effectively disconnected.

one M-L7-1/1/C-DC M-L7-1/2/C-DC
two M-L7-2/1/C-DC M-L7-2/2/C-DC
three M-L7-3/1/C-DC M-L7-3/2/C-DC
four M-L7-4/1/C-DC M-L7-4/2/C-DC
six M-L7-6/1/C-DC M-L7-6/2/C-DC
ten M-L7-10/1/C-DC M-L7-10/2/C-DC
thirteen M-L7-13/1/C-DC M-L7-13/2/C-DC
sixteen M-L7-16/1/C-DC M-L7-16/2/C-DC
twenty M-L7-20/1/C-DC M-L7-20/2/C-DC
twenty-five M-L7-25/1/C-DC M-L7-25/2/C-DC
thirty-two M-L7-32/1/C-DC M-L7-32/2/C-DC
forty M-L7-40/1/C-DC M-L7-40/2/C-DC
fifty M-L7-50/1/C-DC M-L7-50/2/C-DC

M-L7 series high breaking miniature circuit breaker wiring diagram 1

Single pole rated voltage 250V T=4ms

M-L7 series high breaking miniature circuit breaker wiring diagram 2

Two pole rated voltage 500V T=4ms


load capacity
Suitable for unipolar L7 series
Allowable load under corresponding temperature and n switch operating states: IDL=InKT (T) KN (N)

Characteristic curve of M-L7 series high breaking miniature circuit breaker

Temperature data of M-L7 series high breaking miniature circuit breaker

energy consumption
Compliant with EN60898 standard (IEC898)

M-L7 series high breaking miniature circuit breaker characteristic curve 2
M-L7 series high breaking miniature circuit breaker characteristic curve 3

Short circuit capability of M-L7 and fuse D0 or NH
1.4 High selectivity can exceed 1.4kA: □ No selection function
Selective fuses D01, D02, D03

Technical parameters of M-L7 series high breaking miniature circuit breaker


Selective use of fuse NH-00

Selection of fuses for M-L7 series high breaking miniature circuit breakers

M-L7 series high breaking miniature circuit breaker

M-L7 series high breaking miniature circuit breaker
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference