HomeYour location:Homelow-voltage electrical apparatuslow-voltage circuit breakerResidual Current Circuit Breaker → M-FL7 Electromagnetic residual current circuit breaker
Column tabs 
Product name: M-FL7 Electromagnetic residual current circuit breaker
specification: M-FL7 Electromagnetic residual current circuit breaker
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Residual Current Circuit Breaker
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


M-FL7 Electromagnetic residual current circuit breakerDetailed product description:Column tabs
Technical parameters of M-FL7 electromagnetic residual current circuit breaker with overcurrent protection

Compliant with electrical standards: IEC1009 (EN61009)
GB16917.1
Release time: □ Non delayed
a. G has a minimum delay of 10ms
b. Rated voltage (Ue): 230V; 50Hz
c. Rated residual operating current: 10-30300mA
d. Sensitivity: AC type A type
e. Selective level: 3
f. Rated breaking capacity Icn: 10kA
g. Rated current In: 6-40A
h. Release characteristic: C characteristic curve
i. Maximum connectable fuse: 100A gL (>10kA)
j. Resilience to Severe Climate Environment: According to the IEC1009 International Standard
k. Shell protection level: IP40 (after installation)
l. Lifespan: Electrical, no less than 4000 on-off actions
m. Mechanical: no less than 20000 on-off actions
mechanical parameters
a. Shell width: 35mm (2 modules)
b. Installation method: Installed on DIN rail 35mm
c. Terminal wiring capacity: wire 1-25mm2; Mother row thickness 0.8-2mm
d. Attachment: Mother busbar thickness 0.8-2mm
Main Features
The action function is independent of the main line voltage
Equipped with a midline disconnection function, it is safer and more reliable
Dual function terminal block with strong wiring capability
Equipped with a contact status indicator for easy identification of contact status
Breaking capacity up to 10KA
Wide rated current range, suitable for use as a home main switch

Overall dimensions
Installation dimensions of M-FL7 electromagnetic residual current circuit breaker with overcurrent protection

The three protection functions of leakage, overload, and short circuit are integrated. Can prevent misoperation caused by electronic device switch operation.
Rated current In (A) Rated breaking capacity (kA) Lcn Surge protection 250A
Outline drawing 1 of M-FL7 electromagnetic residual current circuit breaker with overcurrent protection1 pole+neutral line
Characteristic diagram 1 of M-FL7 electromagnetic residual current circuit breaker with overcurrent protection
Surge protection 250A pulsating DC sensitive
Outline drawing 2 of M-FL7 electromagnetic residual current circuit breaker with overcurrent protection1 pole+neutral line
Characteristic diagram 2 of M-FL7 electromagnetic residual current circuit breaker with overcurrent protection
C characteristic curve
The breaking performance of M-FL7 electromagnetic residual current circuit breaker with overcurrent protection
Note: C-type can also be used as needed
To provide 2A and 4A products
six
zero point zero three
M-FL7-6/1N/003/C
M-FL7-6/1N/003/C-A
ten
zero point zero three
M-FL7-10/1N/003/C
M-FL7-10/1N/003/C-A
sixteen
zero point zero three
M-FL7-16/1N/003/C
M-FL7-16/1N/003/C-A
twenty
zero point zero three
M-FL7-20/1N/003/C
M-FL7-20/1N/003/C-A
twenty-five
zero point zero three
M-FL7-25/1N/003/C
M-FL7-25/1N/003/C-A
thirty-two
zero point zero three
M-FL7-32/1N/003/C
M-FL7-32/1N/003/C-A
forty
zero point zero three
M-FL7-40/1N/003/C
M-FL7-40/1N/003/C-A
six
zero point zero three
M-FL7-6/1N/003/C
M-FL7-6/1N/003/C-A
ten
zero point zero three
M-FL7-1/1N/003/C
M-FL7-10/1N/003/C-A
sixteen
zero point zero three
M-FL7-16/1N/003/C
M-FL7-16/1N/003/C-A
twenty
zero point zero three
M-FL7-20/1N/003/C
M-FL7-20/1N/003/C-A
twenty-five
zero point zero three
M-FL7-25/1N/003/C
M-FL7-25/1N/003/C-A
thirty-two
zero point zero three
M-FL7-32/1N/003/C
M-FL7-32/1N/003/C-A
forty
zero point zero three
M-FL7-40/1N/003/C
M-FL7-40/1N/003/C-A

The impact of temperature changes in the surrounding environment on the load

Environmental temperature T [℃]
In[A]
-25
-20
-10
0
ten
twenty
thirty
thirty-five
forty
two
two point five
two point four
two point three
two point two
two point two
two point one
two
two
one point nine
four
four point nine
four point eight
four point seven
four point five
four point three
four point two
four
three point nine
three point nine
five
six point two
six
five point eight
five point six
five point four
five point two
five
four point nine
four point eight
six
seven point four
seven point two
seven
six point seven
six point five
six point three
six
five point nine
five point eight
eight
nine point nine
nine point six
nine point three
nine
eight point seven
eight point four
eight
seven point nine
seven point seven
ten
twelve
twelve
twelve
eleven
eleven
ten
ten
nine point nine
nine point seven
twelve
fifteen
fourteen
fourteen
thirteen
thirteen
thirteen
twelve
twelve
twelve
thirteen
sixteen
sixteen
fifteen
fifteen
fourteen
fourteen
thirteen
thirteen
thirteen
fifteen
nineteen
eighteen
seventeen
seventeen
sixteen
sixteen
fifteen
fifteen
fifteen
sixteen
twenty
nineteen
nineteen
eighteen
seventeen
seventeen
sixteen
sixteen
fifteen
twenty
twenty-five
twenty-four
twenty-three
twenty-two
twenty-two
twenty-one
twenty
twenty
ten
twenty-five
thirty-one
thirty
twenty-nine
twenty-eight
twenty-seven
twenty-six
twenty-five
twenty-five
twenty-four
thirty-two
forty
thirty-eight
thirty-seven
thirty-six
thirty-five
thirty-three
thirty-two
thirty-two
thirty-one
forty
forty-nine
forty-eight
forty-seven
forty-five
forty-three
forty-two
forty
thirty-nine
thirty-nine


Release characteristic curve
Characteristic curve of M-FL7 electromagnetic residual current circuit breaker with overcurrent protection

M-FL7 Electromagnetic Leakage Circuit Breaker with Overcurrent Protection

M-FL7 Electromagnetic residual current circuit breaker
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference