| Product name: | ETCR4000 series digital phase voltammetry meter | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- Voltammeter | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
Function |
Phase measurement between any two phases; Measurement of AC current and leakage current; AC voltage measurement; Distinguish between inductive and capacitive circuits, phase sequence of three-phase voltage, and wiring group of transformers, etc |
|
Power supply |
DC9V  Alkaline dry battery LR6 × 6 can be used continuously for about 300 hours |
|
display mode |
3-1/2 LCD display |
|
Instrument size |
Width, height, and thickness: 92mm × 192mm × 50mm |
|
LCD size |
Display area: 64mm × 54mm; Word height: 40mm |
|
Jaw size |
7.5mm (40mm optional) |
|
measurement range |
Phase: 0-360 °; Current: 0-20mA/2A/10A; Voltage: 0-20V/200V/500V |
|
resolution |
Phase: 1 °; Current: 0.1mA; Voltage: 0.01V |
|
measurement accuracy
(50Hz,23℃±1℃,40-60%RH) |
Phase: ± 3 ° |
|
Current: ± 1% ± 2dgt | |
|
Voltage: ± 1.2% ± 2dgt | |
|
Line voltage |
Circuit testing below AC500V |
|
sampling rate |
About 3 times per second |
|
signal frequency |
Sine wave 45Hz~55Hz β=0.05 |
|
data retention |
Data retention function: "DH" symbol display |
|
Backlight function |
Blue screen backlight, suitable for reading in dark places |
|
Auto Shutdown |
After about 15 minutes of startup, the instrument panel automatically shuts down to reduce battery consumption |
|
battery voltage |
When the battery voltage is low, the low battery voltage symbol is displayed, reminding to replace the battery |
|
Instrument quality |
The host weighs about 590g (including battery), the pointed nose current clamp weighs about 175g × 2, and the round mouth high current clamp weighs about 120g |
|
Working temperature and humidity |
-10℃~40℃; Below 85% RH |
|
Storage temperature and humidity |
-20℃~60℃; Below 70% RH |
|
input impedance |
AC voltage input impedance: 2M Ω; voltage input circuit impedance when measuring U1-U2 phase: 40K Ω |
|
insulation resistance |
Between the instrument circuit and the casing, and between the two voltage input terminals: ≥ 10M Ω |
|
Voltage resistance |
Test on the ability to withstand a sine wave AC voltage of 1000V/50Hz between the voltage input terminal and the case, between the clamp current transformer core and clamp handle, and between the secondary winding coils, and between the two voltage input terminals, capable of withstanding a sine wave AC voltage of 500V/50Hz for 1 minute |