HomeYour location:Homelow-voltage electrical apparatusLow voltage transformerDC current transformer → LS series Rogowski coil
Column tabs 
Product name: LS series Rogowski coil
specification: LS series Rogowski coil
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- DC current transformer
Column tabs 
Price: factory price
Brand: 蜀电
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


LS series Rogowski coilDetailed product description:Column tabs
I. Overview
Rogowski coil, also known as current measurement coil or differential current sensor, is a circular coil uniformly wound around a non-magnetic material. The output signal is the derivative of current over time. By integrating the output voltage signal through a circuit, the input current can be accurately restored.

II Structure Introduction:
No ferromagnetic material, no hysteresis effect, almost zero phase error; No magnetic saturation phenomenon, therefore the measurement range can range from several amperes to several hundred kiloamperes of current; The structure is simple and there is no direct circuit connection between it and the measured current; The response bandwidth is 0.1Hz-1MHz. Compared with traditional transformers with iron cores, Rockwell coils have a wide measurement range, high accuracy, stability and reliability, response frequency bandwidth, as well as measurement and relay protection functions. They are small in size, light in weight, safe, and meet environmental requirements.
Based on the Rockwell coil, it has the characteristics of real-time current measurement, fast response speed, no saturation, and almost no phase error. Therefore, it can be applied to relay protection, thyristor rectification, variable frequency speed regulation, resistance welding and other occasions with severe signal distortion.

3、 Electrical parameters:
Input: 5A~100KA
Output: 0-20mA, 0-5V, 0-10V (customer defined)
Grade: 0.5-1%

model
input current
output current
level
Coil length
remark
integrator
Direct output
LS-8200A
200A
0~20mA  0~5V  0~10V
20mV
one
0.4M
Or 3M
The integrator output requires a 24V power supply
For passive
Direct output
LS-8500A
500A
0~20mA  0~5V  0~10V
50mV
LS-81000A
1000A
0~20mA  0~5V  0~10V
1V
LS-82000A
2000A
0~20mA  0~5V  0~10V
2V
LS-83000A
3000A
0~20mA  0~5V  0~10V
3V
LS-84000A
4000A
0~20mA  0~5V  0~10V
4V
LS-85000A
5000A
0~20mA  0~5V  0~10V
5V
LS-810KA
10000A
0~20mA  0~5V  0~10V
10V
LS-820KA
20000A
0~20mA  0~5V  0~10V
20V
LS-830KA
30000A
0~20mA  0~5V  0~10V
30V
LS-850KA
50000A
0~20mA  0~5V  0~10V
50V


LS series Rogowski coil