The JT-5 vacuum high-voltage relay can be used for breaking high-voltage circuits in satellite ground stations, radio communication equipment, radar, and high-voltage electrical devices
2. Technical characteristics: Contact form: one set of conversion or one set of normally open
Coil power supply DC
Coil power consumption 10W
Contact static current 5A
Normal value of contact resistance 0.2 Ω, maximum value 0.5 Ω
Contact rated voltage 50Hz, 20KV (DC or AC peak)
Normal conditions for dielectric withstand voltage: DC or AC 50Hz, 25KV (peak) between contacts and base plate
AC 50Hz, 500V (effective value) between the coil and the base plate
Vibration intensity 50Hz, single amplitude 0.35mm.30 minutes
Impact strength 150m/s 2 1000 times
Lifetime resistance: 27VDC, 0.5A, 105 cycles
Weight 170g
3. Usage conditions
Environmental temperature -40~+55 ℃
Atmospheric pressure 86-106Kpa
Work position arbitrary
4. Coil specifications
at20℃:
| Model number | contact form | rated voltage V | coil resistance Ω±10% | pull-in voltage V | Release voltage V | pull-in voltage ms | Release voltage ms |
JT-5 | 1Z | twenty-seven | eighty | sixteen | five | fifteen | fifteen |
| 1H | twenty-seven | eighty | sixteen | five | fifteen | fifteen |
5. Dimensions and Wiring Diagram of JT-5 Vacuum High Voltage Relay


JT-5 type vacuum high voltage relay