CS1500CF series Hall current sensorDetailed product description:Column tabs
CS1500CF series Hall current sensor electrical parameters

model
CS200CF
CS400CF
CS600CF
CS800CF
CS1000CF
CS1500CF
IPN
Primary rated input current
two hundred
four hundred
six hundred
eight hundred
one thousand
one thousand and five hundred
A
IP
Measurement range of primary current
0~±400
0~±800
0~±1200
0~±1600
0~±2000
0~±2500
A
VOUT
Rated output voltage on the secondary side
4±1%
V
VC
power supply voltage
±12~±15(±5%)
V
IC
current consumption
VC=±15V                        <25
mA
Vd
insulation voltage
5KV effective value/50Hz/1 minute between the primary and secondary circuits
εL
linearity
<1
%FS
V0
Zero offset voltage
TA =25℃                        <±25
mV
VOM
Magnetic misalignment voltage
IPN→0                           <±25
mV
VOT
Unbalanced voltage temperature drift
IP=0  TA =-25~+85℃            <±1
mV
/℃
Tr
response time
≤7
μs
f
Band width (-3dB)
DC~20
kHz
TA
Working environment temperature
-25~+85
TS
Storage environment temperature
-40~+100
RL
load resistor
≥10K
Ω
standard
Q/3201CHGL02-2007

Dimensions (mm)

CS1500CF series Hall current sensor external dimensions
Pin Description: 1:+15V 2: -15V 3: Vout 4:0V (Power Ground) OFS: Zero Point Adjustment GIN: Amplitude Adjustment

Instructions for Use

1. Incorrect wiring may cause damage to the sensor. After the sensor is powered on, when the measured current passes through the direction of the sensor arrow, the in-phase voltage value can be measured at the output terminal.
2. The output amplitude of the sensor can be adjusted appropriately according to user needs.
3. Sensors with different rated input currents and output voltages can be customized according to user needs.