CS2000K Series Hall Removable Current SensorDetailed product description:Column tabs
Product Description: How to Translate
A current sensor based on the open-loop principle of Hall effect can measure currents of DC, AC, pulse, and various irregular waveforms under electrically isolated conditions.

Electrical parameters

model
CS300K
CS500K
CS800K
CS1000K
CS2000K
IPN
Primary rated input current
three hundred
five hundred
eight hundred
one thousand
two thousand
A
IP
Measurement range of primary current
0~±600
0~±1000
0~±1600
0~±2000
0~±2500
A
VOUT
Rated output voltage on the secondary side
4±1%
V
VC
power supply voltage
±12~±15(±5%)
V
IC
Current consumption
VC=±15V                        <25
mA
Vd
insulation voltage
6KV effective value/50Hz/1 minute between the primary and secondary circuits
εL
linearity
<1
%FS
V0
Zero offset voltage
TA =25℃                        <±25
mV
VOM
Magnetic misalignment voltage
IPN→0                           <±30
mV
VOT
Unbalanced voltage temperature drift
IP=0  TA =-25~+85℃            <±1
mV/℃
Tr
response time
≤7
μs
f
Band width (-3dB)
DC~20
kHz
TA
Working environment temperature
-25~+85
TS
Storage environment temperature
-40~+100
RL
Load resistance
≥10K
Ω
standard
Q/3201CHGL02-2007

Dimensions (mm)

CS2000K series Hall detachable current sensor external dimensions
Pin Description: 1:+15V 2: -15V 3: Vout 4:0V (Power Ground) OFS: Zero Point Adjustment GIN: Amplitude Adjustment
Lead output wiring: Red:+15V Blue: -15V Yellow: Vout Black: 0V (power ground)

Instructions for Use
1. Incorrect wiring may cause damage to the sensor. After the sensor is powered on, when the measured current passes through the direction of the sensor arrow, the in-phase voltage value can be measured at the output terminal.
2. The output amplitude of the sensor can be adjusted appropriately according to user needs.
3. Sensors with different rated input currents and output voltages can be customized according to user needs.

CS2000K Series Hall Removable Current Sensor