The CS600BT3 Hall current sensor, which applies the open-loop principle of Hall effect, can measure currents of DC, AC, pulse, and various irregular waveforms under electrical isolation conditions.

Electrical parameters of CS600BT3 Hall current sensor

model CS0100BT3 CS200BT3 CS300BT3 CS400BT3 CS500BT3 CS600BT3
IPN Primary rated input current one hundred two hundred three hundred four hundred five hundred six hundred A
IP Measurement range of primary current 0~±100 0~±200 0~±300 0~±400 0~±500 0~±600 A
VSN Rated output voltage on the secondary side 2±1% V
Vref reference voltage 3±2% V
VC power supply voltage +12(±5%) V
IC current consumption twenty mA
Vd insulation voltage 3KV effective value/50Hz/1 minute between the primary and secondary circuits
εL linearity ±1 %FS
V0 Zero point electrical offset voltage TA=25℃ <±10 mV
VOM Zero point magnetic offset voltage IPN→0 <±10 mV
VOT Unbalanced voltage temperature drift IPN=0 TA=25~85℃ <±1.5 IPN=0 TA=-25~25℃ <±1 mV/℃
VST Gain voltage temperature drift IPNTA=25~85℃ <±1.5 IPNTA=-25~25℃ <±1 mV/℃
Tr response time ≤3 μs
f Band width (-3dB) DC~50 kHz
di/dt Follow accuracy >50 A/us
TA Working environment temperature -25~+85
TS Storage environment temperature -40~+100
RL load resistor ≥10K Ω
m weight About 75 g

Dimensions (mm)

Installation dimensions and characteristic curve of CS600BT3 Hall current sensor
Pin Description:
1. Red line VCC+12V 2, black line 0V power ground 3, brown line Vout output 4, orange line Vref 3V reference voltage OFS, zero point adjustment GIN gain adjustment

Instructions for Use
1. Incorrect wiring may cause damage to the sensor. After the sensor is powered on, when the measured current passes through the direction of the sensor arrow, the in-phase voltage value can be measured at the output terminal.
2. The output amplitude of the sensor can be adjusted appropriately according to user needs.