HomeYour location:Homelow-voltage electrical apparatusLow voltage isolatordisconnecting switch → DGLC series 1000~4000A isolating switches
Column tabs 
Product name: DGLC series 1000~4000A isolating switches
specification: DGLC series 1000~4000A isolating switches
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- disconnecting switch
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


DGLC series 1000~4000A isolating switchesDetailed product description:Column tabs
Usage environment
The DGL series isolating switch can reliably operate under the following conditions
Altitude not exceeding 2000 meters;
The ambient temperature shall not exceed 40 ℃ and shall not be lower than -5 ℃;
Relative humidity not exceeding 95%;
Non explosive hazardous medium environment;
No rain or snow invasion environment;
Note: If it is expected to be used under conditions where the ambient air temperature is above+40 ℃ or below -5 ℃ to -45 ℃, the user should inform the manufacturer.

purpose
AC 50Hz, rated voltage up to 660V, DC rated voltage up to 440V, rated current up to 1600A. Used for infrequent connection and disconnection of circuits.
DGLC Series 1000-4000A Isolation Switch Model Description
table
One normally open and one normally closed
eleven
NO+NC
Two normally open and two normally closed
twenty-two
2NO+2NC


Example of selection: Rated current 630A, with neutral pole conversion and isolation switch, DGL Z-630A/4J for operation outside the cabinet

Outline drawing of DGLC series 1000-4000A isolating switch

DGLC-125~3150A is suitable for circuit connection and disconnection or electrical isolation. There are three levels, four poles, (three poles+switchable neutral pole)
Products with observation windows can be provided as needed to directly observe the on/off status of the contacts.
Direct operation: The handle is installed on the right side of the switch.
External operation: The handle is installed outside the distribution cabinet door.
Two sets of auxiliary contacts can be installed as needed.
Extended shafts are used for external cabinet operations.
The electrical and mechanical properties correspond to the same electrical and mechanical properties as DGL-125 to 3150A.

Assembly drawing of DGLC series 1000-4000A isolating switch

Appearance and installation dimensions
DGLC series 1000-4000A isolating switch external dimensions

Model
External dimensions and installation dimensions
DGLC-1000~3150A
A
B
C
D
E
F
J
K
M
N
P
Q
R
S
T
W
Z
1000A/3
three hundred and seventy-eight
two hundred
two hundred and forty-two
one hundred and fifty-two
one hundred and seventy
forty-seven point five
three hundred and thirty-five
one hundred and seventy-five
eight point five
two hundred and twenty-nine
one hundred and twenty
three hundred and eleven
sixty
fifty-six
eight
two hundred and eighty
two hundred and twenty-four
1000A/4
four hundred and ninety-two
two hundred
two hundred and forty-two
one hundred and fifty-two
one hundred and seventy
forty-seven point five
four hundred and seventy
one hundred and seventy-five
eight point five
two hundred and eighty-nine
one hundred and twenty
three hundred and eleven
sixty
fifty-six
eight
two hundred and eighty
two hundred and twenty-four
1250A/3
three hundred and seventy-eight
two hundred
two hundred and forty-two
one hundred and fifty-two
one hundred and seventy
forty-seven point five
three hundred and thirty-five
one hundred and seventy-five
eight point five
two hundred and twenty-nine
one hundred and twenty
three hundred and eleven
eighty
sixty-nine
eight
two hundred and eighty
two hundred and twenty-four
1250A/4
four hundred and ninety-two
two hundred
two hundred and forty-two
one hundred and fifty-two
one hundred and seventy
forty-seven point five
four hundred and seventy
one hundred and seventy-five
eight point five
two hundred and eighty-nine
one hundred and twenty
three hundred and eleven
eighty
sixty-nine
eight
two hundred and eighty
two hundred and twenty-four
1600A/3
three hundred and seventy-eight
two hundred
two hundred and forty-two
one hundred and fifty-two
one hundred and seventy
forty-seven point five
three hundred and thirty-five
one hundred and seventy-five
eight point five
two hundred and twenty-nine
one hundred and twenty
three hundred and eleven
eighty
sixty-nine
ten
two hundred and eighty
two hundred and twenty-four
1600A/4
four hundred and ninety-two
two hundred
two hundred and forty-two
one hundred and fifty-two
one hundred and seventy
forty-seven point five
four hundred and seventy
one hundred and seventy-five
eight point five
two hundred and eighty-nine
one hundred and twenty
three hundred and eleven
eighty
sixty-nine
ten
two hundred and eighty
two hundred and twenty-four
2000A/3
three hundred and seventy-eight
two hundred
three hundred and thirty-five
two hundred and forty
two hundred and sixty
forty-seven point five
three hundred and thirty-five
one hundred and seventy-five
eight point five
two hundred and twenty-nine
one hundred and twenty
three hundred and eleven
eighty
one hundred and twenty-seven
ten
two hundred and eighty
two hundred and twenty-four
2000A/4
four hundred and ninety-two
two hundred
three hundred and thirty-five
two hundred and forty
two hundred and sixty
forty-seven point five
four hundred and seventy
one hundred and seventy-five
eight point five
two hundred and eighty-nine
one hundred and twenty
three hundred and eleven
eighty
one hundred and twenty-seven
ten
two hundred and eighty
two hundred and twenty-four
2500A/3
three hundred and seventy-eight
two hundred
three hundred and thirty-five
two hundred and forty
two hundred and sixty
forty-seven point five
three hundred and thirty-five
one hundred and seventy-five
eight point five
two hundred and twenty-nine
one hundred and twenty
three hundred and eleven
eighty
one hundred and twenty-seven
ten
two hundred and eighty
two hundred and twenty-four
2500A/4
four hundred and ninety-two
two hundred
three hundred and thirty-five
two hundred and forty
two hundred and sixty
forty-seven point five
four hundred and seventy
one hundred and seventy-five
eight point five
two hundred and eighty-nine
one hundred and twenty
three hundred and eleven
eighty
one hundred and twenty-seven
ten
two hundred and eighty
two hundred and twenty-four
3150A/3
three hundred and seventy-eight
two hundred
three hundred and thirty-five
two hundred and forty
two hundred and sixty
forty-seven point five
three hundred and thirty-five
one hundred and seventy-five
eight point five
two hundred and twenty-nine
one hundred and twenty
three hundred and eleven
one hundred and twenty
one hundred and fifty-seven
twelve
two hundred and eighty
two hundred and twenty-four
3150A/4
four hundred and ninety-two
two hundred
three hundred and thirty-five
two hundred and forty
two hundred and sixty
forty-seven point five
four hundred and seventy
one hundred and seventy-five
eight point five
two hundred and eighty-nine
one hundred and twenty
three hundred and eleven
one hundred and twenty
one hundred and fifty-seven
twelve
two hundred and eighty
two hundred and twenty-four


DGLC series 1000-4000A isolating switch

DGLC series 1000~4000A isolating switches
  • Related product tags  Related Products:
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference