| Product name: | SR92 Series 0.3 Grade PID Regulator | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- industrial control equipment | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
Number |
SR92 is a 0.3 level PID intelligent regulator with dual four position display, dual output, analog transmission output, digital communication, disconnection alarm, upper and lower limit alarm and other functions. The front panel protection level is IP66. | |||||||
|
SR92- |
DIN standard: height 72 x width 72 x depth 110mm, panel opening size 68 x 68mm | |||||||
|
Input type and measurement range (Display range of DC input type -1999-9999 and decimal point position can be set) |
eight free input |
Thermocouple: B:0~1800,R:0~1700,S:0~1700,K1:100.0~400.0,K2:0.0~800.0,K3:-200~1200,E:0~700,J:0~600,T:-199.9~200.0,N:0~1300,PLII:0~1300,Wre5-26:0~2300,U:-199.9~200.0,L:0~600 ℃ Pt100 platinum resistance: -200~600, -100.0~100.0, -50.0~50.0, 0.0~200.0 ℃ (JPt100 omitted) DC millivolt -10~10, 0~10, 0~20, 0~50, 10~50, 0~100mV | ||||||
|
four |
DC current: 0-20mA, 4-20mA, input impedance: 250 Ω | |||||||
|
six |
DC voltage: -1~1, 0~1, 0~2, 0~5, 1~5, 0~10V Input impedance: 500K Ω | |||||||
|
Adjust output (1) type |
Y- |
Relay contact, proportional cycle 1-120 seconds, contact capacity: 240V AC 2A resistive | ||||||
|
I- |
Current 4-20mA DC, load impedance<600 Ω | |||||||
|
P- |
Solid state relay drive, proportional cycle 1-120 seconds, 12 ± 1.5V DC/maximum 30mA | |||||||
|
V- |
Voltage 0-10V DC, load current<2mA | |||||||
|
Adjust output (2) type Positive and negative effects can be set (Optional) |
N- |
nothing | ||||||
|
Y- |
Relay contact, proportional cycle 1-120 seconds, contact: 240V AC 2A resistive | |||||||
|
I- |
Current 4-20mA DC, load impedance<600 Ω | |||||||
|
P- |
Solid state relay drive, proportional cycle 1-120 seconds, 12V ± 1.5V DC/maximum 30mA | |||||||
|
V- |
Voltage 0-10V DC, load current<2mA | |||||||
|
power supply |
90- |
100~240V AC±10%(50/60Hz) | ||||||
|
08- |
24V AC/DC±10%(50/60Hz) | |||||||
|
Event output (optional) (When the heater is disconnected, only the output (1) can be adjusted. It is optional when it is a Y-shaped/P-type output.) |
0 |
nothing | ||||||
|
one |
Event output: EV1, EV2 Contact: 240V AC 1A/resistive | |||||||
|
two |
Event output: EV1 and 30A heater disconnection alarm (contact: 1.5A/resistive) | |||||||
|
three |
Event output: EV1 and 50A heater disconnection alarm (contact: 1.5A/resistive) | |||||||
|
Isolation analog transmission (optional) |
0 |
nothing | ||||||
|
three |
0~10mV DC, Output impedance: 10 Ω | |||||||
|
four |
4~20mA DC, Load impedance<300 Ω | |||||||
|
six |
0~10V DC, Load current<2 mA | |||||||
|
Digital communication interface or dual set value (SB) (Choose one) |
0 |
nothing | ||||||
|
five |
RS485 address: 1-255 | |||||||
|
seven |
RS232C | |||||||
|
eight |
1 point (range: -1999~5000), no voltage contact or OC gate input | |||||||
SR92 Series 0.3L PID Regulator