| Product name: | 0.3 Economy class PID regulator | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- industrial control equipment | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
| project | code | Double four digit digital display, measurement accuracy of ± 0.3% of full range+1 word, sampling twice per second, self-tuning PID parameters. Equipped with manual, power on slow start, adjustable output limit, and no overshoot expert PID | ||||
| 1. Type | SR73A- | DIN standard height 96 x width 96 x depth 110mm opening size: 92 x 92mm | ||||
| SR74A- | Standard 96 × 48 × 110mm 92 × 45mm | |||||
| 2. Input type and measurement range. The display range and decimal point position of DC input type can be set |
eight free input |
Thermocouples: 11 types, 22 measurement ranges (Hua Shi omitted): B: 0~1800 R: 0~1700S: 0~1700 K1: -100~400 K2: 0~1200 E: 0~700 J: 0~600T: -199.9~200.0 N: 0~1300 U: -199.9~200.0 L: 0~600 ℃. Platinum resistance: Pt100 or JPt100 standard, with 16 measurement ranges (Hua Shi omitted): -200~600, -100.0~100.0, -50.0~50.0, 0.0~200.0 ℃. Millivolt voltage: 0-10, 10-50, 0-100; The display range can be set from -1999 to 9999. | ||||
| four | Current: 4-20mA accepts impedance of 250 Ω; The display range can be set from -1999 to 9999. | |||||
| six | Voltage (V): 0-1,1-5,0-10; The display range can be set from -1999 to 9999. | |||||
| 3. Adjust the output type (adjustment methods: PID, PD, PI, P, and positional) | P | Solid state relay SSR driving voltage output: proportional period 1-120 seconds can be set; Level: 15V ± 3VDC/20mA (at 1.5K load) | ||||
| Y | Relay contact: proportional cycle 1-120 seconds can be set; 240VAC: 2.5A/pure resistance 1A/inductive load. | |||||
| I | Linear current output: 4-20mA DC, output impedance below 600 Ω. | |||||
| V | Linear voltage output: 0-10V DC, load current below 2mA. | |||||
|
4. Alarm and option types The independent upper and lower limit alarm relay output is the basic configuration, and four alarm modes can be set. Single phase heater disconnection alarm (optional) Note: Only applicable to Y1 or P1 output type instruments SB set value offset (optional) |
one | Independent upper and lower limit alarm relay contact capacity: 240VAC 1.5A (pure resistance). | ||||
| three | Upper and lower limit alarm+wire breakage alarm (detection from 0.0 to 50.0A) | |||||
| five | Upper and lower limit alarm+SB set value offset (dual set value) | |||||
| A | Upper and lower limit alarm+special disconnection alarm (0-5VDC input) | |||||
| 5. Isolation digital communication interface option type, communication distance up to 1.2 kilometers, can link up to 100 instruments | 0 | No interface | ||||
| five | RS - 485 | |||||
| six | RS - 422A | |||||
SR73A/74A economical 0.3-level PID regulator