project |
number |
Special computer design, dual four digit display, accuracy (± 0.25%+1 word), sampling speed of 4 times/second, PID self-tuning, "no overshoot" expert PID algorithm P: 0.1-999.0% FS I: 1-8000S D: 0-3600S Ordinary limiting and special linear limiting, time scale and timer output | ||||||||||||
|
one |
SR52 |
DIN height 72 x width 72 x depth 110mm opening: 68 x 68mm | ||||||||||||
|
SR53 |
Standard 96 x width 96 x depth 110mm 92 x 92mm | |||||||||||||
|
SR54 |
Size 96 x Width 48 x Depth 110mm 92 x 45mm | |||||||||||||
|
2. Input type and measurement range (configurable measurement value filtering and offset functions) |
one |
14 types of thermocouples B: 0-1800 R: 0-1700 S: 0-1700 E: 0.0-700.0 J:0.0~600.0 K:-100.0~400.0 K:0.0~800.0 K:0~1200 T:-199.0~200.0 N:0~1300 PLⅡ:0~1300 WRe5-26:0~2300 U:-199.9~200.0 L:0.0~600.0℃. | ||||||||||||
|
two |
Pt100 or JPt100 (BA2) platinum resistance standard, with 36 measurement ranges available (Fahrenheit omitted) -200~600,-100.0~100.0,-100.0~300.0,-50.0~50.0, 0.00~50.00,0.00~99.99,0.0~100.0,0.0~200.0,0.0~500.0 | |||||||||||||
|
three |
Linear voltage DC (mV): 0-10, 0-20, 0-50, 0-100, 10-50, -10 to 10 |
Digital display range programmable | ||||||||||||
|
four |
Linear current DC (mA): 4-20, 0-20 | |||||||||||||
|
six |
Linear voltage DC (V): 0-1,0-2,5,0-10,1-5, -1-1 | |||||||||||||
|
3. Isolation regulation control output (methods: PID, PD, PI, P, and positional) |
Y |
Relay contact: Proportional cycle 1-120 seconds, 240VAC 2.5A (pure resistance) 1A inductive | ||||||||||||
|
I |
Linear output current: 4-20mA DC acceptance impedance below 600 Ω | |||||||||||||
|
P |
SSR driving voltage: proportional cycle 1-120 seconds 15V ± 3V DC/20mA | |||||||||||||
|
V |
Linear output voltage: 0-10V DC below 2mA | |||||||||||||
|
4. Power supply (The following are options) |
90- |
100~240V AC ±10% SR52/53 13 W SR54 15 W | ||||||||||||
|
10- 02- |
24V AC±10% 50/60Hz 24V DC±10% | |||||||||||||
|
5.10 segment programmable |
N |
0 | ||||||||||||
|
P |
Programmable 10 segments | |||||||||||||
|
6. Event relay output alarm and 17 event configurations |
0 |
nothing | ||||||||||||
|
one |
SR52, 2-point EV1, EV2/HB; SR53/54:3 Point EV1, EV2, EV3/HB | |||||||||||||
|
7. Isolation cascade (analog remote control) input can set remote control input value filtering and offset |
00 |
nothing |
Application: Cascade regulation, or area control composed of SR50,25 and FP21 with analog transmission | |||||||||||
|
fourteen |
4-20mA DC acceptance impedance:<250 Ω | |||||||||||||
|
fifteen |
1-5V DC input impedance:>500K Ω | |||||||||||||
|
sixteen |
0-10V DC input impedance:>500k Ω | |||||||||||||
|
8. Y, P-type output single-phase heater disconnection (HB)/heating circuit (HL) alarm/load current monitoring |
0 |
nothing | ||||||||||||
|
one |
Monitoring: 0.1-30.0A Contact: Pure Resistance 240 VAC 1.5A | |||||||||||||
|
9. Square root operation of voltage and current input |
0 |
nothing | ||||||||||||
|
one |
Used for traffic conversion | |||||||||||||
|
10. Isolate analog transmission output (Internally, set value SV or measured value PV can be sent) Isolation digital communication interface (can be equipped with Himanton optical isolation RS232/422/485 communication converter) Note: Only one of analog transmission and digital communication can be selected. SR52 does not provide communication interface |
00 |
nothing | ||||||||||||
|
03 |
Voltage 0-10mV output impedance: 10 Ω | |||||||||||||
|
04 |
Current 4-20mA load impedance: below 300 Ω | |||||||||||||
|
06 |
Voltage 0-10V, maximum load current:<2mA | |||||||||||||
|
fifteen |
RS-485 |
1200,2400,4800,9600 Distance: 485, 422 1.2km 232 15m Address: 00-31 | ||||||||||||
|
sixteen |
RS-422A | |||||||||||||
|
seventeen |
RS-232C | |||||||||||||
SR50 series 0.25 level ten segment programmable PID controller