HomeYour location:HomeHigh voltage electrical applianceshigh-voltage circuit breakerSF6 gas circuit breaker → LW36-126 Outdoor high-voltage sulfur hexafluoride circuit breaker
Column tabs 
Product name: LW36-126 Outdoor high-voltage sulfur hexafluoride circuit breaker
specification: LW36-126 Outdoor high-voltage sulfur hexafluoride circuit breaker
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- SF6 gas circuit breaker
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


LW36-126 Outdoor high-voltage sulfur hexafluoride circuit breakerDetailed product description:Column tabs
The LW36-126 outdoor self powered high-voltage sulfur hexafluoride circuit breaker is suitable for use in AC 50Hz, 110kV power systems. It can be used as a control and protection equipment for power systems, as well as as as a contact circuit breaker. This product was awarded the 2001 National Economic and Trade Commission Key New Product Recommendation Certificate.

Main technical characteristics of LW36-126 outdoor high-voltage sulfur hexafluoride circuit breaker

1. The circuit breaker adopts the principle of self extinguishing arc, with strong breaking capacity, and can break up to 20 times at full capacity;  
2. Equipped with a new type of highly reliable spring operated mechanism, the mechanical reliability can reach 60000 times;  
3. Equipped with CT24 or new spring mechanism, high mechanical reliability and low maintenance workload;  
4. High insulation level, able to meet both national and IEC standards simultaneously;  
5. Thick steel plate integral frame with high seismic resistance.

Main technical parameters of LW36-126 outdoor high-voltage sulfur hexafluoride circuit breaker:
serial number project unit Technical Parameters
one altitude m 1000(3000)
two ambient temperature -25~+40
three rated voltage kV one hundred and twenty-six
four rated current A 2500 3150
five rated frequency Hz fifty
six Rated short-circuit breaking current kA 31.5 40
seven Rated short-circuit closing current kA 80 100
eight Rated short-time withstand current kA 31.5 40
nine Rated peak withstand current kA 80 100
ten Rated short-time power frequency withstand voltage kV Ground: 230 Between fracture surfaces: 230+73*
eleven Rated lightning impulse withstand voltage kV Ground: 550 Between fracture: 550+103*
twelve Rated short-circuit current duration s four
thirteen Rated out of step breaking current A 8 10
fourteen Near area fault breaking current 90% 75%
fifteen Rated line charging switching current A thirty-one point five
sixteen Rated operating sequence O-0.3s-CO-180s-CO
seventeen SFsixGas pressure (20 ℃ gauge pressure) MPa zero point six
eighteen mechanical life time six thousand
nineteen Control circuit voltage V DC110 or 220


LW36-126 Outdoor High Voltage Sulfur Hexafluoride Circuit Breaker

LW36-126 Outdoor high-voltage sulfur hexafluoride circuit breaker
Product Category