| Product name: | TS3000 series frequency converter | ||||||
| specification: | ![]() |
||||||
| Category: | motor products -- Variable Frequency Drive (VFD) | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
Project |
Standardization | ||||||||||||
|
Rated output voltage |
Three phase 380V (maximum output voltage is the same as input power supply voltage) | ||||||||||||
|
Rated output power of adaptive motor (KW) |
zero point seven five |
two point two |
five point five |
eleven |
eighteen point five |
thirty |
forty-five |
seventy-five |
one hundred and ten |
one hundred and sixty |
two hundred and twenty |
two hundred and eighty | |
|
one point five |
four |
seven point five |
fifteen |
twenty-two |
thirty-seven |
fifty-five |
ninety |
one hundred and thirty-two |
two hundred |
two hundred and fifty |
three hundred and fifteen | ||
|
Rated output current (A) |
two point five |
five |
thirteen |
twenty-five |
thirty-eight |
sixty |
ninety |
one hundred and fifty |
two hundred and ten |
three hundred |
four hundred and twenty |
five hundred and forty | |
|
three point seven |
nine |
sixteen |
thirty-two |
forty-five |
seventy-five |
one hundred and ten |
one hundred and seventy |
two hundred and fifty |
three hundred and eighty |
four hundred and eighty |
six hundred | ||
|
Continuous operating current |
100% rated output current | ||||||||||||
|
overload capacity |
150% rated output current for 2 minutes, 180% rated output current for 10 seconds | ||||||||||||
|
output frequency |
0Hz~400Hz | ||||||||||||
|
Rated input voltage |
Three phase 380V ± 20%, 50~60Hz ± 5% | ||||||||||||
|
modulation scheme |
Optimizing Space Voltage Vector PWM Modulation Mode | ||||||||||||
|
Control method |
There is PG feedback vector control; No PG feedback vector control; V/F control | ||||||||||||
|
Given method for running commands |
Keyboard given; External terminal given; Given by the upper computer through the serial communication port | ||||||||||||
|
Speed setting method |
Keyboard numeric settings; Simulation setting; Serial communication settings for the upper computer; Six methods including pulse frequency setting | ||||||||||||
|
Speed setting resolution |
Digital setting: 0.01Hz | ||||||||||||
|
Accuracy of speed setting |
Digital setting: ± 0.01% maximum frequency (-10 ℃~+40 ℃); | ||||||||||||
|
Speed control accuracy |
PG feedback vector control: ± 0.05% rated speed; (25℃±10℃) | ||||||||||||
|
Speed control range |
PG feedback vector control: 1:1000; | ||||||||||||
|
Torque control response |
PG feedback vector control:<150mS; | ||||||||||||
|
Starting torque |
PG feedback vector control: 200% rated output torque/0.05Hz; | ||||||||||||
|
Braking torque |
Energy free braking:>20% rated output torque within 22KW,>15% rated output torque above 30KW | ||||||||||||
|
Torque control accuracy |
± 5% rated output torque | ||||||||||||
|
Set reference voltage output |
1 route,+10V, 5mA | ||||||||||||
|
Control voltage source output |
24 V,100mA; It can also be provided externally through PLC terminals | ||||||||||||
|
External user power input |
1 way, the working power supply of the contact input terminal can use an external active contact power supply (12-24V) | ||||||||||||
|
analog output |
1 channel, 0~10V, programmable output, multiple output options available | ||||||||||||
|
Programmable contact input |
7-channel programmable, with 27 optional functions including forward/reverse, forward/reverse jog, multi-stage speed, multi-stage acceleration/deceleration time, free parking, voltage/current switching, etc | ||||||||||||
|
Pulse signal input |
1 channel, 0~50K HZ | ||||||||||||
|
PG signal input |
A+, A -, B+, B - differential input; A -, B - Open collector code wheel input | ||||||||||||
|
FAM frequency signal output |
1 channel, frequency meter signal (output frequency is the multiplier signal of the frequency converter output frequency), 0-50kHz | ||||||||||||
|
Open collector output |
2 channels, 24 operating states to choose from; Maximum output current 50mA | ||||||||||||
|
Programmable relay output |
2 channels, 24 operating states to choose from, contact capacity: 250V AC/3A or 30V DC/1A | ||||||||||||
|
Serial communication interface |
RS-485 interface | ||||||||||||
|
standard functions |
Current limiting, torque boost, speed tracking, DC braking, power outage restart, slip compensation, automatic fault reset, frequency upper and lower limit limits, bias frequency, starting frequency, jump frequency, frequency gain, carrier frequency adjustment, adjustable acceleration/deceleration mode, voltmeter output, ammeter output, multi-stage speed, program operation, swing frequency operation, PI closed-loop operation, proportional linkage, remote control, forward and reverse dead zone | ||||||||||||
|
protection function |
Overvoltage, undervoltage, overcurrent, current limiting, overload, overheating, electronic thermal overload relay, overvoltage stall, data protection, etc | ||||||||||||
|
Four digit digital display (LED) |
Set 16 state parameters including frequency, output frequency, output voltage, output current, motor speed, output torque, switch terminal, programming menu parameters, and 31 fault codes | ||||||||||||
|
Chinese LCD display |
Control mode, current programming or monitoring parameter name, alarm content, keyboard operation guidance, etc | ||||||||||||
|
Indicator light (LED) |
Parameter units, RUN/STOP status, etc | ||||||||||||
|
Terms of Use |
Installation site |
Indoor, altitude not exceeding 1000 meters, dust-free, non corrosive gases, no direct sunlight | |||||||||||
|
Applicable Environment |
-10 ℃~+40 ℃ (bare machine -10 ℃~+50 ℃), 20%~90% RH (no condensation) | ||||||||||||
|
vibration |
Less than 0.5g | ||||||||||||
|
Storage method |
-25℃~+65℃ | ||||||||||||
|
Installation method |
Wall mounted, floor standing electrical control cabinet type | ||||||||||||
|
Protection level |
IP20 | ||||||||||||
|
cooling method |
0.75KW and below are enclosed self cooling, while others are forced air cooling | ||||||||||||
TS3000 series frequency converter