HomeYour location:HomeHigh voltage electrical appliancesElectric display deviceHigh voltage sensor → DXN series indoor high-voltage live display device
Column tabs 
Product name: DXN series indoor high-voltage live display device
specification: DXN series indoor high-voltage live display device
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- High voltage sensor
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


DXN series indoor high-voltage live display deviceDetailed product description:Column tabs
DXN series indoor high-voltage live display device

2.2 Classification of Display Devices
a. Divided by rated voltage level: 3, 6, 10, 27.5, 35KV;
b. According to the environmental conditions of sensor usage, it can be divided into: ordinary type, reinforced insulation type (all working condition type);
c. Divided by sensor structure and installation dimensions: see Table 2;
d. Divided by display function: T-shaped, Q-type;
e. Divided by the external dimensions of the monitor: Type I, Type II; Refer to Figures 8 and 9;

2.3 Basic parameters of display device
The basic parameters of the display device are shown in Table 1

Table 1

Project Name
unit
data
sensor
rated voltage
KV
three
six
ten
twenty
twenty-seven point five
thirty-five
Maximum operating voltage Um
three point five
six point nine
eleven point five
thirty-one point five
forty point five
rated frequency
Hz
fifty
Insulation level
Power frequency withstand voltage (effective value)
Once to twice to the ground
KV
twenty-five
thirty-two
forty-two
sixty-five
eighty
one hundred
Lightning impulse withstand voltage (peak value)
forty
sixty
seventy-five
one hundred and twenty-five
one hundred and eighty-five
one hundred and eighty-five
partial discharge
PC
≤10
bending strength
KN
eight
monitor
Neon lamp ignition voltage
KV
zero point five two
zero point eight seven
one point seven three
two point three eight
three point zero three
Locking start control voltage
one point nine five
three point nine zero
six point five zero
thirteen
seventeen point eight eight
twenty-two point seven five
Secondary lockout power supply voltage
V
220    -100

Note: If the voltage of the secondary locking power supply exceeds the specifications in Table 1, it shall be resolved through consultation between the user and the manufacturer.

3. Structure Overview
The sensors and displays of the display device are connected through external wires to form a capacitive voltage divider circuit (see schematic diagram in Figure 1)

Schematic diagram of DXN series indoor high-voltage live display device

3.1 Sensors
The sensor is made of pillar insulator type and embedded with high-strength dielectric functional material to form a core rod capacitor C1. One end of C1 is connected to the high-voltage bus through an upper flange, and the other end of C1 is connected to the lower end (secondary terminal) of the sensor (see Figure 2). The external structure of the sensor is made into different heights and various umbrella skirts according to the matching requirements (as shown in Figure 4-7). According to installation requirements, the upper flange is made with single screw holes, double screw holes, and four screw holes (specific hole diameter, hole spacing, and hole number are shown in Table 2). There are two types of external insulation structures for sensors:
a. The sensor is made of an outer insulation sleeve made of high-voltage porcelain cloth, with a high-voltage capacitor C1 buried in the middle, and its model is CG1 (see Figure 2).
b. The sensor is made of outer insulation sleeve and high-voltage capacitor C1, made of SMC material with flame retardancy and hydrophobicity, and made of silk. Its model is CG3 (see Figure 3).

Outline drawing of DXN series indoor high-voltage live display device
DXN series indoor high-voltage live display device installation size 1
3.2 Monitor
The display functions include prompt type and forced type. The prompt type has single display (i.e. three sensors with one display, wiring principle shown in Figure 10) and dual display (i.e. three sensors with two displays, wiring principle the same as single display), with the two displays installed on two different sides of the switchgear. Warning neon lights are not allowed to rest. Compulsory type: It not only has all the functions of prompt type, but also uses pumping signals to control electronic switches and cooperates with electromagnetic locks to perform compulsory locking. When only one phase of the three-phase circuit is charged, the electromagnetic lock cannot be unlocked. The direct key switch in the monitor is used to select the working and resting status of the neon lamp. When the neon lamp is in a resting state, the strong wire locking circuit cannot be unlocked (see wiring principle in Figure 11).
Note: Type I displays come in two types: prompt type and forced locking type.
The Type II monitor only has a prompt type and does not have a forced locking function.
4. Appearance and installation dimensions
4.1 The appearance and installation dimensions of the sensor are shown in Figure 4-7 and Table 2.
DXN series indoor high-voltage live display device installation size 2
DXN series indoor high-voltage live display device installation size 3

DXN series indoor high-voltage live display device

DXN series indoor high-voltage live display device
Product Category