| Product name: | CD17,CD17A series electromagnetic actuator | ||||||
| specification: | ![]() |
||||||
| Category: | spare parts and accessories -- Electric operating mechanism | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
serial number |
Model |
rated voltage |
closing coil |
trip coil | ||
|
Calculated current A |
Resistance (ohms) |
Calculated current A |
Resistance (ohms) | |||
|
one |
CD17-I |
220V |
seventy-one |
three |
one point five |
one hundred and forty-six |
|
110V |
one hundred and forty-two |
zero point seven seven |
three |
thirty-six point five | ||
|
two |
CD17-Ⅱ |
220V |
eighty-nine |
two point five |
one point five |
one hundred and forty-six |
|
110V |
one hundred and seventy-eight |
zero point six one |
three |
thirty-six point five | ||
|
three |
CD17-Ⅲ |
220V |
one hundred and thirty-eight |
one point six |
one point five |
one hundred and forty-six |
|
110V |
two hundred and seventy-six |
zero point four |
three |
thirty-six point five | ||
|
four |
CD17A-I |
220V |
eighty-nine |
two point five |
one point five |
one hundred and forty-six |
|
110V |
one hundred and seventy-eight |
zero point six one |
three |
thirty-six point five | ||
|
five |
CD17A-Ⅱ |
220V |
one hundred and twenty-eight |
one point seven two |
one point five |
one hundred and forty-six |
|
110V |
two hundred and fifty-six |
zero point four three |
three |
thirty-six point five | ||
|
six |
CD17A-Ⅲ |
220V |
one hundred and seventy |
one point three |
one point five |
one hundred and forty-six |
|
110V |
three hundred and forty |
zero point three |
three |
thirty-six point five | ||
2. The coil of the mechanism operates on a short-term working system, and its operating power supply is DC.
3. The reliable closing voltage of the institution is 85% to 110% of the rated working voltage. The reliable tripping voltage is 65% to 120% of the rated working voltage, and the mechanism shall not trip when the rated working voltage is less than 30%.
4. Between the conductive part and the grounding part, and between the conductive parts of different circuits. 1min power frequency withstand voltage 2000V, there should be no flashover or breakdown phenomenon. The coil can withstand 2.5 times the rated operating voltage between turns.
5. The working angle of the output shaft of this institution is 50 °~55 °, and the service life of the institution is 10000 times.
Main technical parameters
Schematic diagram of CD17 structure
Schematic diagram of CD17A structure