| Product name: | 711 type preset counter | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- electronic counter | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
The 711 preset counter is based on the latest manufactured integrated circuits, with highly integrated circuit components and a keyboard design that meets international standards, making it easy and safe to use; The AC power supply unit also provides a 24VDC/60mA power supply for the electronic pulse generator, with a six digit digital display and zero blanking function. Applied to packaging machinery and printing machinery.
711-400 relay output, negative edge triggered counter
711-410 relay output, positive edge triggers counter
711-424 transistor output, negative edge triggered counter
711-427 transistor output, positive edge trigger counter
Schematic diagram of programming switch:
Product series and related technical parameters:
|
function |
Programming switch | |||||||
|
S1 |
S2 |
S3 |
S4 |
S5 |
S6 |
S7 | ||
|
Reset input |
low frequency |
left |
||||||
|
high frequency |
right |
|||||||
|
Counting pulse input |
low frequency |
left |
||||||
|
High lock |
right |
|||||||
|
Pre input |
lock |
left |
||||||
|
gating |
right |
|||||||
|
automatic loop |
is |
left |
||||||
|
No |
right |
|||||||
|
Work mode input |
set |
left |
||||||
|
reset |
right |
|||||||
|
counting method |
decrease |
left |
||||||
|
increasing |
right |
|||||||
|
Keyboard reset |
lock |
left | ||||||
|
gating |
right | |||||||
| counter | |
| display | 7-segment red LED display |
| digit | 6 people |
| character height | 7mm |
| power supply voltage | 12-24VDC ± 10%, 220VAC (with power pack) |
| power consumption | VOP=12V,Imax=120mA |
| External fuse | 250mA |
| data saving | About 10 years |
| Counting pulse and reset pulse | |
| input impedance | 22K |
| Threshold voltage | High level>=8V, low level<=2V |
| Permission input voltage | Positive and negative 40V |
| Trigger along | Positive or negative edge (depending on the model) |
| Extreme counting frequency | 5KHz, 30Hz during plastic surgery |
| Minimum pulse period | 100us, 17ms during plastic surgery |
| output | |
| relay output | The minimum signal cycle is 50ms |
| Adjustable or bistable | |
| Contact load 50VA | |
| Transistor output | About 50ms or set as bistable |
| Switching voltage VOP/0V | |
| Maximum switch current 40mA | |
| other | |
| protection level | Level 2 |
| Front panel protection | IP 54,DIN 40050 |
| Plug in protection | IP 00,DIN 40050 |
| Safety Instructions | VDE 0411 |
| anti-interference capability | IEC 801, Level 3 |
| Operating Temperature | -10 degrees to+50 degrees |
| Storage temperature | -20 degrees to+70 degrees |
Installation dimension diagram: