HomeYour location:Homelow-voltage electrical apparatusLow-voltage fuse → RH-01 thermal fuse
Column tabs 
Product name: RH-01 thermal fuse
specification: RH-01 thermal fuse
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Low-voltage fuse
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


RH-01 thermal fuseDetailed product description:Column tabs
Purpose:
Coil products (power supplies, transformers, motors, chargers, etc.); Network communication equipment (switches, routers, central office devices, etc.) and various household appliances

Characteristics and working principle:
RH-01 thermal fuse is a small sealed structure, disposable overheat protector. Under normal circumstances, the fuse can maintain the reliable operation of the protected product. When the protected product experiences abnormalities and the temperature continues to rise, exceeding the rated temperature of the fuse, the melt inside the fuse immediately melts, quickly disconnecting the circuit and protecting the product from damage.
Technical specifications:
Rated electrical performance: AC 250V; 1A;2A; 3A
Disconnecting temperature: 95-145 ° C
Action deviation: -10 ° C
Insulation strength: AC 50HZ 500V (between leads),
AC 50HZ 1500V (between the lead wire and the uncharged shell), no breakdown or flashover for 1 minute

technical parameters

model

Type

No.

Rated action

temperature

(Tf)

Actual measured operating temperature

Maintain temperature

(TH/TC)

extreme temperature

(TM)

rated current

(Ir)

rated voltage

(Ur)

RH95

95℃

93±2℃

68℃

110℃

1A~3A

250V

RH102

102℃

98±2℃

76℃

120℃

1A~3A

250V

RH115

115℃

113±2℃

85℃

140℃

1A~3A

250V

RH125

125℃

122±3℃

97℃

150℃

1A~3A

250V

RH130

130℃

126±3℃

102℃

160℃

1A~3A

250V

RH135

135℃

131±3℃

105℃

165℃

1A~3A

250V

RH140

140℃

137±3℃

115℃

180℃

1A~3A

250V

RH145

145℃

142±3℃

120℃

180℃

1A~3A

250V


Ordering and usage instructions:
Users must accurately measure the actual temperature of the location where the fuse link is installed after thermal stability based on the characteristics of their product, and determine the operating temperature of the fuse link through matching tests, and then propose the operating temperature value for ordering.
When using soldering or spot welding, it is important to avoid overheating and damaging the temperature fuse

RH-01 thermal fuse
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference