| Product name: | JKG series reactive power automatic compensation controller | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- Compensation equipment | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
2、 Main technical parameters
1. Controller setting value and adjustable range:
a. Input threshold COS φ=0.95, continuously adjustable from 0.90 to 0.98
b. The cut-off threshold COS φ=0.99 (lag) 0.98 (lag) 0.99 (lead) is continuously adjustable.
c. Overvoltage protection 250V/433V 230V/400V-255V/442V continuously adjustable.
d. Undercurrent blockade 300mA 100-400mA continuously adjustable.
e. The delay time is continuously adjustable from 20 ± 5 seconds to 10-90 seconds.
2. Rated working voltage Us AC 220V 50Hz
3. Current sampling input I S AC>5A 50Hz impedance; < 0.2Ω
4. Number of output circuits: 4, 6, 8, 10 circuits
5. Relay contact capacity: AC 220V 10V, 380V 5A (resistive)
6. Dielectric strength: continuous
7. Work schedule: A controller with automatic phase recognition function can be provided continuously according to user requirements. And the sampling voltage is 380V, 110V, and the controller.
3、 JKG series reactive power automatic compensation controller usage environment
Indoor
Altitude 2500 meters
The ambient temperature shall not exceed 40 ℃ and shall not be lower than -5 ℃
The air temperature should not exceed 50% at 40 ℃ and 90% at 22 ℃
The surrounding environment is free of corrosive gases, conductive dust, and flammable and explosive media.
There is no severe vibration at the installation location
The voltage fluctuation range shall not exceed -10% -+15%.
4、 Reactive power automatic compensation controller
|
Preface |
model |
specification |
voltage |
Overall dimensions (Width x Height x Depth) |
Opening size (Width x Height) |
Main features |
|
one |
JKGF |
4. 6, 8 10 circuits |
220V |
170×110×150 |
162×102mm |
1. Automatic cycle switching 2. The pointer table displays COS φ |
|
two |
JKG |
4. 6, 8 10 circuits |
220V |
120×120×120 |
113×113mm Same as Table 42L6 |
1. Automatic cycle switching 2. The pointer table displays COS φ |
|
three |
JKGFC |
4. 6, 8 10 circuits |
220V |
170×110×150 |
162×102mm |
1. Automatic cycle switching 2. Digital display COS φ 3. Automatic identification |
|
four |
JKG2B |
4. 6, 8 10 circuits |
220V |
170×110×150 |
162×102mm |
1. Automatic cycle switching 2. Digital display COS φ 3. Automatic identification 4. Manual switching |
|
five |
JKG2C |
4. 6, 8 10 circuits |
220V |
170×110×150 |
113×113mm Same as Table 42L6 |
1. Automatic cycle switching 2. Digital display COS φ 3. Automatic identification 4. Manual switching |
A controller with automatic phase recognition function can be provided according to user requirements. And controllers with sampling voltages of 380V and 110V.