HomeYour location:Homelow-voltage electrical apparatusMaster Electrical ApplianceMaster controller → LK17 series master controller
Column tabs 
Product name: LK17 series master controller
specification: LK17 series master controller
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Master controller
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


LK17 series master controllerDetailed product description:Column tabs
The LK17 series is a non adjustable master controller that adopts the IEC standard. It has an advanced and reasonable structure, reliable operation, and easy operation. Compared with LK1 products, it reduces volume and weight by two-thirds, and increases electrical and mechanical life by 2-3 times. It has high mechanical performance. The contact of this product has a double break point, bridge structure, and strong arc extinguishing ability. The DC contains permanent magnet blocks for arc extinguishing. So the installation, use, and maintenance of this controller are extremely convenient, making it an ideal replacement product.  
Purpose:

LK17 series master controller, with a specified heating current of 10A, suitable for AC 50HZ, 380V and below, and DC 220V and below. Used for frequent switching of control circuits in transmission.
technical parameters

(1) The mechanical lifespan of the controller shall not be less than 3 million cycles, and the electrical lifespan shall not be less than 1 million cycles.
(2) The number of contacts in the controller is 2-12, and the left and right positions are 1-6.
(3) According to the different requirements of the controlled circuit, the master controller creates various working charts.
(4) The contact connection and disconnection capability of the controller meets the requirements of AC AC-11 and DC DC-11.

See table:

controller

Rated control

Connection conditions

Breaking conditions

category

Capacity (VA or W)

Voltage (V)

Current (A)

COSФ

L/R(ms)

Voltage (V)

Current (A)

COSФ

L/R(ms)

AC-11 communication

one thousand

three hundred and eighty

forty-two

0.15

/

three hundred and eighty

2.6

0.20

/

DC-11 DC

one hundred and eighty

two hundred and twenty

5.7

/

fifty

two hundred and twenty

0.8

/

two hundred


Appearance and installation dimensions of the controller

Outline dimensions of LK17 series master controller

model

size

L

H

LK17-6/101

110±0.5

one hundred and seventy

LK17-12/604

190±0.5

two hundred and forty-five


According to the different requirements of the circuit, the controller is made into various contacts, and the working chart is as follows:
LK17 series master controller contact diagram 1
LK17 series master controller contact diagram 2
LK17 series master controller contact diagram 3
LK17 series master controller contact diagram 4
LK17 series master controller contact diagram 5
LK17 series master controller contact diagram 6
LK17 series master controller contact diagram 7
LK17 series master controller contact diagram 8
LK17 series master controller contact diagram 9
LK17 series master controller contact diagram 10
LK17 series master controller contact diagram 11
LK17 series master controller contact diagram 12
LK17 series master controller contact diagram 13
LK17 series master controller contact diagram 14
LK17 series master controller contact diagram 15
LK17 series master controller contact diagram 16
LK17 series master controller contact diagram 17
LK17 series master controller contact diagram 18
LK17 series master controller contact diagram 19
LK17 series master controller contact diagram 20
LK17 series master controller contact diagram 21
LK17 series master controller contact diagram 23
LK17 series master controller contact diagram 22
LK17 series master controller contact diagram 24
LK17 series master controller contact diagram 25
LK17 series master controller contact diagram 26
LK17 series master controller contact diagram 27
LK17 series master controller contact diagram 28
LK17 series master controller contact diagram 29
LK17 series master controller contact diagram 30
LK17 series master controller contact diagram 31
LK17 series master controller contact diagram 32
LK17 series master controller contact diagram 33
LK17 series master controller contact diagram 34
LK17 series master controller contact diagram 35


Usage and maintenance
1. Equipped with terminal blocks for easy wiring, the arc extinguishing chamber adopts a double break bridge structure. Therefore, the electrical and mechanical lifespan is several times longer than that of old products.  
2. Maintenance is extremely convenient. No need for special tools. Long term use, if the current contact opening distance is less than 3 millimeters, the contact should be replaced in a timely manner, and attention should be paid to AC and DC.  
3. When using and maintaining on site, attention should be paid to safety and live working is strictly prohibited. When carrying out live work, safety equipment and protective gear should be worn, and someone should supervise to prevent accidents from occurring.  
4. When placing an order, the model of the controller must be marked as AC (J) or DC (Z).
LK17 series master controller
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference