| Product name: | YDQ series liquid resistance starter | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- soft starter | ||||||
| Price: | factory price | ||||||
| Brand: | 大力 | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||

| model | Applicable motor capacity (KW) | Start time (S) | Structural form and weight |
| YDQ5-0.2 series | Below 200 | 20~60 | Integrated 200kg |
| YDQ5-0.4 series | Below 400 | 20~60 | Integrated 350kg |
| YDQ5-0.6 series | Below 600 | 20~60 | Integrated 450kg |
| YDQ3-0.6 series | Split 600kg | ||
| YDQ5-1 series | Below 2000 | 20~60 | Integrated 550kg |
| YDQ3-1 series | Split 700kg | ||
| YDQ5-2 series | Below 3000 | 20~60 | Integrated 600kg |
| YDQ3-2 series | Split 750kg | ||
| YDQ5-3 series | Below 4000 | 20~60 | Integrated 720kg |
| YDQ3-3 series | Split 840kg | ||
| YDQ5-4 series | Below 5000 | 20~60 | Integrated 820kg |
| YDQ3-4 series | Split 970kg | ||
| YDQ5-6 series | Below 7000 | 20~60 | Integrated 1050kg |
| YDQ3-6 series | Split 1200kg |
Normal working conditions:
The upper limit of environmental temperature shall not exceed 50 ℃, and the lower limit shall not be lower than -5 ℃; Relative humidity not exceeding 85%; The altitude should not exceed 2000M; it should be placed indoors without severe vibration and impact, with a vertical inclination of no more than 5 °, and without fire or explosion hazards; No conductive dust or corrosive gases from Egypt are allowed; The power supply adopts three-phase four wire 380/220V 20A, and the voltage fluctuation must be ensured within ± 15% of the rated voltage.
Note: When the ambient temperature remains below 0 ℃ for a long time, a heater needs to be installed. Users should specify this when placing an order
Usage and maintenance:
1. There are two spare switches on the starter control cabinet panel:
Parking button: can be used for emergency parking on site;
Start button: can be used for on-site starting according to user needs.
2. Before starting the equipment, power must be supplied to the control cabinet, and it can only be started when the "allow start" signal light is on.
3. The electrolyte is usually replaced every 4-5 years, and the electrode plate and insulation box are cleaned at the same time. The electrode plate can be cleaned by first corroding the conductive surface with dilute hydrochloric acid and then rinsing with clean water. The insulation box can be cleaned by first rinsing with clean water and then drying, and then coated with epoxy resin several times (in general, it is best not to disassemble and clean, and vibration and impact should be avoided during disassembly to prevent the box from breaking).
Appearance and installation dimensions:
This starter is a cabinet structure, and the protection level can reach IP43 according to user requirements. According to different auxiliary functions, there are two types: integrated and split, and the structural form can be configured according to user requirements. The basic structural form and external dimensions of the split type are shown in Figure 2 and Table 2; The basic structural form and external dimensions of the integration are shown in Figure 3 and Table 3.

Table 2 YDQ3 Series Appearance and Installation Dimensions
|
model |
Appearance of control cabinet
Size mm |
Control cabinet installation
Size mm |
Appearance of resistor cabinet
Size mm |
Installation of resistance cabinet
Size mm | |||||||||
|
A1 |
B1 |
C1 |
E1 |
F1 |
Φ |
A |
B |
C |
E |
F |
Φ | ||
|
YDQ3-0.6 series |
seven hundred |
six hundred |
two thousand |
five hundred and fifty |
four hundred and fifty |
nine hundred |
eight hundred |
two thousand |
seven hundred and fifty |
seven hundred and ten |
|||
|
YDQ3-1 series |
seven hundred |
six hundred |
two thousand |
five hundred and fifty |
four hundred and fifty |
sixteen |
one thousand |
nine hundred |
two thousand |
eight hundred and fifty |
eight hundred and ten |
sixteen | |
|
YDQ3-2 series |
seven hundred |
six hundred |
two thousand |
five hundred and fifty |
four hundred and fifty |
one thousand |
nine hundred |
two thousand |
eight hundred and fifty |
eight hundred and ten |
|||
|
YDQ3-3 series |
eight hundred |
six hundred |
two thousand |
six hundred and fifty |
four hundred and fifty |
one thousand and two hundred |
one thousand and one hundred |
two thousand and two hundred |
one thousand and fifty |
one thousand and ten |
|||

Table 3 YDQ5- Series Appearance and Installation Dimensions
|
model |
Dimensions mm |
Installation size mm | ||||
|
A |
B |
C |
E |
F |
Φ | |
|
YDQ5-0.2 series |
seven hundred |
seven hundred |
one thousand and eight hundred |
five hundred and fifty |
six hundred and ten |
sixteen |
|
YDQ5-0.4 series |
eight hundred |
eight hundred |
two thousand |
six hundred and fifty |
seven hundred and ten |
sixteen |
|
YDQ5-0.6 series |
nine hundred |
eight hundred |
two thousand |
seven hundred and fifty |
seven hundred and ten |
sixteen |
|
YDQ5-1 series |
one thousand |
nine hundred |
two thousand |
eight hundred and fifty |
eight hundred and ten |
sixteen |
|
YDQ5-2 series |
one thousand and two hundred |
one thousand and one hundred |
two thousand |
one thousand and fifty |
one thousand and ten |
sixteen |
|
YDQ5-3 series |
one thousand and four hundred |
one thousand two hundred and sixty |
two thousand and two hundred |
one thousand two hundred and fifty |
one thousand one hundred and twenty |
sixteen |
|
YDQ5-4 series |
1500* |
one thousand and five hundred |
two thousand five hundred and fifty |
1350* |
one thousand and two hundred |
sixteen |
|
YDQ5-6 series |
2600* |
one thousand and five hundred |
two thousand five hundred and fifty |
2450* |
one thousand and two hundred |
sixteen |