HomeYour location:Homelow-voltage electrical apparatusstartersoft starter → YDQ series liquid resistance starter
Column tabs 
Product name: YDQ series liquid resistance starter
specification: YDQ series liquid resistance starter
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- soft starter
Column tabs 
Price: factory price
Brand: 大力
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


YDQ series liquid resistance starterDetailed product description:Column tabs
Application scope:
The YDQ series liquid resistance starter (hereinafter referred to as the starter) is a new type of starter developed to improve the starting performance of large and medium-sized wound AC asynchronous motors. It overcomes the problems of high impact current, difficult starting, and inconvenient operation of frequency sensitive resistance starters, and is suitable for heavy-duty starting of motors such as ball mills, air compressors, crushers, large fans, and large water pumps in industrial sectors such as building materials, metallurgy, chemical industry, and mining. It is an ideal substitute for frequency sensitive starters and metal resistance starters.
This product adopts patented technology.

Model Description:
Model Description of YDQ Series Liquid Resistance Starter
The meaning of auxiliary code:
W multi-point temperature measurement and sound and light alarm function
J equipped with automatic camera transfer function
K low-voltage motor primary circuit
Short circuit contactor with two contactors in parallel
B Short circuit contactor with vacuum contactor
PC adopts programmable controller
Each auxiliary code can be combined to complete the corresponding function.

Basic principle:
This starter gradually reduces the distance between two parallel plates in the conductive liquid through a mechanical transmission device until it reaches zero, causing the resistance value in the motor rotor circuit to gradually decrease smoothly from maximum to zero, and gradually smoothing the motor speed to reach the rated speed. Thus achieving smooth starting of heavy-duty wound large and medium-sized motors.  
Technical performance characteristics:
1. The starting current is small and constant, with no impact on the power grid; The starting current should not exceed 1.3 times the rated current, thus reducing the requirement for transformer capacity during motor overload starting and minimizing one-time investment;
2. Smooth starting reduces the impact on mechanical equipment and can extend the lifespan of mechanical equipment and motors by about 30%;
3. Large heat capacity, can be started continuously 5-10 times;
4. Low voltage can still start, as long as the grid voltage can ensure the normal operation of the motor, smooth starting can be guaranteed;
5. The structure is simple, easy to maintain, and the reliability is superior to frequency sensitive and oil immersed variable resistors.

model Applicable motor capacity (KW) Start time (S) Structural form and weight
YDQ5-0.2 series Below 200 20~60 Integrated 200kg
YDQ5-0.4 series Below 400 20~60 Integrated 350kg
YDQ5-0.6 series Below 600 20~60 Integrated 450kg
YDQ3-0.6 series Split 600kg
YDQ5-1 series Below 2000 20~60 Integrated 550kg
YDQ3-1 series Split 700kg
YDQ5-2 series Below 3000 20~60 Integrated 600kg
YDQ3-2 series Split 750kg
YDQ5-3 series Below 4000 20~60 Integrated 720kg
YDQ3-3 series Split 840kg
YDQ5-4 series Below 5000 20~60 Integrated 820kg
YDQ3-4 series Split 970kg
YDQ5-6 series Below 7000 20~60 Integrated 1050kg
YDQ3-6 series Split 1200kg


Normal working conditions:
The upper limit of environmental temperature shall not exceed 50 ℃, and the lower limit shall not be lower than -5 ℃; Relative humidity not exceeding 85%; The altitude should not exceed 2000M; it should be placed indoors without severe vibration and impact, with a vertical inclination of no more than 5 °, and without fire or explosion hazards; No conductive dust or corrosive gases from Egypt are allowed; The power supply adopts three-phase four wire 380/220V 20A, and the voltage fluctuation must be ensured within ± 15% of the rated voltage.
Note: When the ambient temperature remains below 0 ℃ for a long time, a heater needs to be installed. Users should specify this when placing an order

Usage and maintenance:
1. There are two spare switches on the starter control cabinet panel:
Parking button: can be used for emergency parking on site;
Start button: can be used for on-site starting according to user needs.
2. Before starting the equipment, power must be supplied to the control cabinet, and it can only be started when the "allow start" signal light is on.
3. The electrolyte is usually replaced every 4-5 years, and the electrode plate and insulation box are cleaned at the same time. The electrode plate can be cleaned by first corroding the conductive surface with dilute hydrochloric acid and then rinsing with clean water. The insulation box can be cleaned by first rinsing with clean water and then drying, and then coated with epoxy resin several times (in general, it is best not to disassemble and clean, and vibration and impact should be avoided during disassembly to prevent the box from breaking).

Appearance and installation dimensions:
This starter is a cabinet structure, and the protection level can reach IP43 according to user requirements. According to different auxiliary functions, there are two types: integrated and split, and the structural form can be configured according to user requirements. The basic structural form and external dimensions of the split type are shown in Figure 2 and Table 2; The basic structural form and external dimensions of the integration are shown in Figure 3 and Table 3.


Dimensions of YDQ series liquid resistance starter

Table 2 YDQ3 Series Appearance and Installation Dimensions

model
Appearance of control cabinet
Size mm
Control cabinet installation
Size mm
Appearance of resistor cabinet
Size mm
Installation of resistance cabinet
Size mm
A1
B1
C1
E1
F1
Φ
A
B
C
E
F
Φ
YDQ3-0.6 series
seven hundred
six hundred
two thousand
five hundred and fifty
four hundred and fifty
nine hundred
eight hundred
two thousand
seven hundred and fifty
seven hundred and ten
YDQ3-1 series
seven hundred
six hundred
two thousand
five hundred and fifty
four hundred and fifty
sixteen
one thousand
nine hundred
two thousand
eight hundred and fifty
eight hundred and ten
sixteen
YDQ3-2 series
seven hundred
six hundred
two thousand
five hundred and fifty
four hundred and fifty
one thousand
nine hundred
two thousand
eight hundred and fifty
eight hundred and ten
YDQ3-3 series
eight hundred
six hundred
two thousand
six hundred and fifty
four hundred and fifty
one thousand and two hundred
one thousand and one hundred
two thousand and two hundred
one thousand and fifty
one thousand and ten


Installation dimensions of YDQ series liquid resistance starter
Table 3 YDQ5- Series Appearance and Installation Dimensions

model
Dimensions mm
Installation size mm
A
B
C
E
F
Φ
YDQ5-0.2 series
seven hundred
seven hundred
one thousand and eight hundred
five hundred and fifty
six hundred and ten
sixteen
YDQ5-0.4 series
eight hundred
eight hundred
two thousand
six hundred and fifty
seven hundred and ten
sixteen
YDQ5-0.6 series
nine hundred
eight hundred
two thousand
seven hundred and fifty
seven hundred and ten
sixteen
YDQ5-1 series
one thousand
nine hundred
two thousand
eight hundred and fifty
eight hundred and ten
sixteen
YDQ5-2 series
one thousand and two hundred
one thousand and one hundred
two thousand
one thousand and fifty
one thousand and ten
sixteen
YDQ5-3 series
one thousand and four hundred
one thousand two hundred and sixty
two thousand and two hundred
one thousand two hundred and fifty
one thousand one hundred and twenty
sixteen
YDQ5-4 series
1500*
one thousand and five hundred
two thousand five hundred and fifty
1350*
one thousand and two hundred
sixteen
YDQ5-6 series
2600*
one thousand and five hundred
two thousand five hundred and fifty
2450*
one thousand and two hundred
sixteen

Note: 1. When selecting a vacuum circuit breaker for the rotor short-circuit contactor with * size, an additional 1100 must be added
2. The structure of the liquid resistance starter for larger capacity motors shall be designed and manufactured separately according to user requirements.

Installation Instructions
1. It is best to install the liquid resistance cabinet on a cement platform that can drain water;
2. The installation ground should be level, and the cabinet should be installed vertically and horizontally;
3. The resistance cabinet should be installed directly above the cable duct and equipped with a channel steel base (Figure 6);
4. The motor rotor cable is connected to the copper bar connected to the liquid resistor at the bottom of the short-circuit contactor on the back of the resistance cabinet through a cable trench (the copper bar is equipped with rotor wiring screws and nuts);
5. If equipped with an in camera, the rotor cable first goes to the in camera, and then connects to the resistor cabinet from the in camera;
6. The control power supply uses 3 × 2.5+1 × 1.5mm2 cables to connect A, B, C, and N on terminal block X1 to the starter. Connect the interlocking control lines between the liquid starter and the primary cabinet, DCS system, or other central control systems according to the drawing.
7. Install green and yellow grounding wires on the grounding pole.


Installation diagram of YDQ series liquid resistance starter

YDQ series liquid resistance starter

YDQ series liquid resistance starter