Preface |
parameter name |
unit |
Product coil rated voltage type parameter requirements | |||||
|
12V |
24V |
30V |
36V |
40V |
48A | |||
|
one |
Rated control power supply voltage of coil |
V |
twelve |
twenty-four |
thirty |
thirty-six |
forty |
forty-eight |
|
two |
Maximum starting current of coil |
A |
<5 | |||||
|
three |
Maximum holding current of coil in cold state |
A |
zero point five five |
zero point three |
zero point two five |
zero point two |
zero point one seven |
zero point one six |
|
four |
Rated operating voltage of contact circuit |
V |
twenty-four |
forty-eight |
thirty |
thirty-six |
forty |
forty-eight |
|
five |
Rated working current of contact circuit |
A |
two hundred | |||||
|
six |
Control the fluctuation range of power supply voltage |
- |
±20%Us | |||||
|
seven |
Maximum breaking capacity of contacts |
A |
4Ie power on time is 5 milliseconds, with 5 on-off cycles (τ=0.001 seconds) | |||||
|
eight |
Contact voltage drop under 100A current |
MV |
<60 | |||||
|
nine |
Pull in time under rated control power supply voltage |
MS |
<30 | |||||
|
ten |
Release time under rated control power supply voltage |
MS |
<30 | |||||
|
eleven |
Maximum bounce time of the contact point |
MS |
three | |||||
|
twelve |
Insulation resistance value (cold state) |
MΩ |
>20 | |||||
|
thirteen |
AC insulation electrical strength |
- |
50Hz 1000V 1min | |||||
|
fourteen |
Auxiliary contact load current |
A |
5A τ=0.001s (only products with "S" have this option) 24V | |||||
|
fifteen |
Electrical lifespan (£=0.001 seconds) |
time |
1000 (τ=0.001 seconds) | |||||
|
sixteen |
mechanical life |
ten thousand times |
thirty | |||||
|
seventeen |
Work Specifications |
- |
continuous | |||||
|
eighteen |
Action characteristics |
V |