| Product name: | ZXN Pneumatic Thin Film Double Seat Regulating Valve | ||||||
| specification: | ![]() |
||||||
| Category: | Pump valve fittings -- control valve | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
valve body, valve cover |
50ZG core, valve seat |
Packing material |
bellows |
gasket |
Membrane cover |
Ripple membrane |
spring |
Valve stem, push rod |
bushing |
Soft seal valve core |
|
HT200 |
1Cr18Ni9Ti, Stellite alloy overlay welding |
Polytetrafluoroethylene, flexible graphite |
1Cr18Ni9Ti |
Rubber asbestos board, 10 #, 1Cr18Ni9Ti, asbestos wrapped gasket |
A3 |
Dingqing rubber clip reinforced polyester fabric |
60SiMn |
2Cr13、1Cr18Ni9Ti |
2Cr13 |
Enhanced polytetrafluoroethylene |
|
Nominal diameter DN (mm) |
twenty-five |
thirty-two |
forty |
fifty |
sixty-five |
eighty |
one hundred |
one hundred and twenty-five |
one hundred and fifty |
two hundred | |||
|
Rated flow coefficient ( KV) |
straight line |
twelve point one |
nineteen point four |
thirty point three |
forty-eight point three |
seventy-five point nine |
one hundred and twenty-one |
one hundred and ninety-three point six |
three hundred and two point five |
four hundred and eighty-four |
seven hundred and fifty-nine | ||
|
equal percentage |
eleven |
seventeen point six |
twenty-seven point five |
forty-four |
sixty-nine point three |
one hundred and ten |
one hundred and seventy-six |
two hundred and seventy-five |
four hundred and forty |
six hundred and ninety-three | |||
|
Rated travel L (mm) |
sixteen |
twenty-five |
forty |
sixty | |||||||||
|
Effective area of membrane Ae (cm2) |
two hundred and eighty |
four hundred |
six hundred |
one thousand | |||||||||
|
Nominal pressure PN (MPa) |
1.6, 4.0, 6.4 | ||||||||||||
|
Inherent flow characteristics |
Straight line, equal percentage | ||||||||||||
|
inherent adjustable ratio |
fifty | ||||||||||||
|
Signal range Pr (KPa) |
20~100, 40~200, 20~60, 60~100, 80~240 | ||||||||||||
|
Gas source pressure Ps (MPa) |
0.14~0.4 | ||||||||||||
|
Allowable leakage rate (l/h) |
Level II (5 × 10-3 × valve rated capacity) Level IV (10-3 × valve rated capacity) | ||||||||||||
|
Working temperature t (℃) |
Room temperature type |
-20-200, -40~250, -60~250 | |||||||||||
|
heat dissipation type |
-40-450, -60~450 | ||||||||||||
|
high-temperature type |
450~650 | ||||||||||||
|
Low temperature type |
-60~-100, -100~-200, -200~-250 | ||||||||||||
|
Area Ae (cm2) |
two hundred and eighty |
four hundred |
six hundred |
one thousand |
||||||
|
Signal range Pr (KPa) |
20-100 |
40-200 |
20-100 |
40-200 |
20-100 |
40-200 |
20-100 |
40-200 | ||
|
Gas source pressure Ps (MPa) |
zero point one four |
zero point two five |
zero point one four |
zero point two five |
zero point one four |
zero point two five |
zero point one four |
zero point two five | ||
|
Accessories required |
- |
P |
- |
P |
- |
P |
- |
P | ||
|
public call, name, say, weigh through path DN ( mm) and valve seat straight path d (mm) |
twenty-five |
twelve |
five point five seven |
six point four zero |
||||||
|
thirty-two |
fifteen |
six point one six |
six point four zero |
|||||||
|
forty |
twenty |
five point five seven |
six point four zero |
|||||||
|
twenty-five |
six point one six |
six point four zero |
||||||||
|
four point nine zero |
six point four zero |
|||||||||
|
fifty |
twenty-five |
six point one six |
six point four zero |
|||||||
|
thirty-two |
four point nine zero |
six point four zero |
||||||||
|
forty |
three point nine zero |
six point four zero |
||||||||
|
sixty-five |
thirty-two |
four point four eight |
six point four zero |
|||||||
|
eighty |
forty |
three point nine zero |
six point four zero |
|||||||
|
fifty |
four point four eight |
six point four zero |
||||||||
|
sixty-five |
three point six three |
six point four zero |
||||||||
|
one hundred |
fifty |
four point four eight |
six point four zero |
|||||||
|
sixty-five |
three point six three |
six point four zero |
||||||||
|
seventy |
two point nine zero |
six point four zero |
||||||||
|
one hundred and twenty-five |
sixty-five |
three point eight five |
six point four zero | |||||||
|
one hundred and fifty |
seventy |
two point eight nine |
six point four zero | |||||||
|
one hundred |
three point eight five |
six point four zero | ||||||||
|
one hundred and twenty-five |
three point two zero |
six point four zero | ||||||||
|
two hundred |
one hundred |
three point eight five |
six point four zero | |||||||
|
one hundred and twenty-five |
three point two zero |
six point four zero | ||||||||
|
one hundred and fifty |
one point six zero |
four point eight one | ||||||||
| Connection standard for dynamic film dual seat regulating valve: | ||||||||
|