| Product name: | ZXS type pneumatic thin film angular single seat regulating valve | ||||||
| specification: | ![]() |
||||||
| Category: | Pump valve fittings -- control valve | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
valve body, valve cover |
Valve core and seat |
Soft seal valve core |
filler |
bellows |
Fill in the sheet |
Membrane cover |
Ripple membrane |
spring |
Valve stem, push rod |
bushing |
|
HT200,ZG230-450,ZG1Cr18Ni9Ti |
1Cr18Ni9Ti, Stellite alloy overlay welding |
Enhanced polytetrafluoroethylene |
Polytetrafluoroethylene, flexible graphite |
1Cr18Ni9Ti |
Rubber asbestos board, 1Cr18Ni9Ti, asbestos wrapped gasket |
A3 |
Dingqing rubber clip reinforced polyester fabric |
60Si2Mn |
2Cr13、1Cr18Ni9Ti |
2Cr13 |
|
Nominal diameter DN (mm) |
twenty |
twenty-five |
thirty-two |
forty |
fifty |
sixty-five |
eighty |
one hundred |
one hundred and twenty-five |
one hundred and fifty |
two hundred | |||||
|
Valve seat diameter dn (mm) |
( 10) |
( 12) |
( 15) |
( 20) | ||||||||||||
|
Rated flow coefficient ( KV) |
straight line |
one point eight |
two point eight |
four point four |
six point nine |
eleven |
seventeen point six |
twenty-seven point five |
forty-four |
sixty-nine |
one hundred |
one hundred and seventy-six |
two hundred and seventy-five |
four hundred and forty |
six hundred and ninety | |
|
equal percentage |
one point six |
two point five |
four |
six point three |
ten |
sixteen |
twenty-five |
forty |
sixty-three |
one hundred |
one hundred and sixty |
two hundred and fifty |
four hundred |
six hundred and thirty | ||
|
Rated travel L (mm) |
sixteen |
twenty-five |
forty |
sixty | ||||||||||||
|
Effective area of membrane Ae (cm2) |
two hundred and eighty |
four hundred |
six hundred |
one thousand | ||||||||||||
|
Nominal pressure PN (MPa) |
1.6 4.0 6.4 | |||||||||||||||
|
Inherent flow characteristics |
Straight line, equal percentage | |||||||||||||||
|
inherent adjustable ratio |
fifty | |||||||||||||||
|
Signal range Pr (KPa) |
20~100, 40~200, 20~60, 60~100, 80~240 | |||||||||||||||
|
Gas source pressure Ps (MPa) |
0.14~0.4 | |||||||||||||||
|
Allowable leakage rate (l/h) |
Hard valve core: Grade IV Soft valve core: Grade VI | |||||||||||||||
|
Working temperature t (℃) |
Room temperature type |
-20-200, -40~250, -60~250 | ||||||||||||||
|
heat dissipation type |
-40-450, -60~450 | |||||||||||||||
|
high-temperature type |
450~650 | |||||||||||||||
|
Low temperature type |
-60~-100, -100~-200, -200~-250 | |||||||||||||||
|
Nominal diameter (DN) |
twenty |
twenty-five |
thirty-two |
forty |
fifty |
sixty-five |
eighty |
one hundred |
one hundred and twenty-five |
one hundred and fifty |
two hundred | ||||||||||||
|
A |
two hundred and eighty-two |
two hundred and eighty-two |
three hundred and eight |
three hundred and eight |
three hundred and eight |
three hundred and ninety-four |
three hundred and ninety-four |
three hundred and ninety-four |
four hundred and ninety-eight |
four hundred and ninety-eight |
four hundred and ninety-eight | ||||||||||||
|
L |
PN16 |
ninety-five |
one hundred |
one hundred and five |
one hundred and fifteen |
one hundred and twenty-five |
one hundred and forty-five |
one hundred and fifty-five |
one hundred and seventy-five |
two hundred |
two hundred and twenty-five |
two hundred and seventy-five | |||||||||||
|
PN40 |
ninety-five |
one hundred |
one hundred and five |
one hundred and fifteen |
one hundred and twenty-five |
one hundred and forty-five |
one hundred and fifty-five |
one hundred and seventy-five |
two hundred |
two hundred and twenty-five |
two hundred and seventy-five | ||||||||||||
|
PN64 |
one hundred and fifteen |
one hundred and fifteen |
one hundred and thirty |
one hundred and thirty |
one hundred and fifty |
one hundred and seventy |
one hundred and ninety |
two hundred and fifteen |
two hundred and fifty |
two hundred and seventy-five |
three hundred and twenty-five | ||||||||||||
|
H |
Pu through type |
PN16 |
three hundred and forty-nine |
three hundred and fifty |
three hundred and fifty-eight |
three hundred and seventy-eight |
three hundred and ninety-three |
four hundred and ninety-four |
five hundred and three |
five hundred and twenty-one |
six hundred and thirty-four |
six hundred and ninety-six |
seven hundred and fifteen | ||||||||||
|
PN40 |
three hundred and forty-nine |
three hundred and fifty |
three hundred and fifty-eight |
three hundred and seventy-eight |
three hundred and ninety-three |
four hundred and ninety-four |
five hundred and three |
five hundred and twenty-one |
six hundred and thirty-four |
six hundred and ninety-six |
seven hundred and fifteen | ||||||||||||
|
PN64 |
three hundred and fifty |
three hundred and fifty-seven |
three hundred and ninety |
three hundred and ninety-eight |
four hundred and twenty |
five hundred and ten |
five hundred and forty-two |
five hundred and sixty |
six hundred and two |
seven hundred |
seven hundred and sixty-two | ||||||||||||
|
high-temperature type |
four hundred and forty-four |
four hundred and forty-five |
four hundred and fifty-eight |
four hundred and seventy-eight |
four hundred and ninety-three |
five hundred and ninety-four |
six hundred and twenty-eight |
six hundred and forty-six |
seven hundred and fifty-nine |
eight hundred and forty-six |
nine hundred and fifteen | ||||||||||||
|
Bellows type |
four hundred and nineteen |
four hundred and twenty-three |
four hundred and forty-four |
four hundred and seventy-eight |
four hundred and ninety |
five hundred and eighty-two |
six hundred and twenty-four |
six hundred and nineteen |
seven hundred and fifty-nine |
eight hundred and forty |
eight hundred and four | ||||||||||||
|
low warm type |
D 4 |
PN 16 PN 40 |
two hundred and ninety |
two hundred and ninety |
three hundred and fifteen |
three hundred and thirty-five |
three hundred and seventy |
four hundred |
four hundred and thirty-five |
four hundred and ninety |
five hundred and fifty-five |
six hundred and thirty |
seven hundred and forty | ||||||||||
|
D 3 |
PN 16 PN 40 |
two hundred and sixty |
two hundred and sixty |
two hundred and eighty-five |
three hundred and five |
three hundred and forty |
three hundred and seventy |
four hundred and five |
four hundred and sixty |
five hundred and twenty-five |
five hundred and ninety |
seven hundred | |||||||||||
|
N-D |
8-14 |
8-16 |
10-16 |
12-18 |
14-18 |
16-18 |
18-18 | ||||||||||||||||
|
Low temperature type |
Normal height+(10-20)% | ||||||||||||||||||||||
|
heavy quantity (kg) |
Pu through type |
PN16 |
sixteen |
seventeen |
nineteen |
twenty-one |
twenty-three |
thirty-five |
forty-eight |
fifty-seven |
sixty-four |
seventy |
ninety | ||||||||||
|
PN40 |
sixteen |
seventeen |
nineteen |
twenty-one |
twenty-three |
thirty-five |
forty-eight |
sixty |
sixty-seven |
seventy-four |
ninety-five | ||||||||||||
|
PN64 |
twenty |
twenty-one |
twenty-five |
thirty |
thirty-three |
forty-four |
seventy-one |
ninety-one |
one hundred |
one hundred and fifteen |
one hundred and forty-five | ||||||||||||
|
high-temperature type |
seventeen |
eighteen |
twenty |
fifty-five |
twenty-five |
thirty-six |
fifty-one |
sixty |
sixty-seven |
seventy-four |
ninety-five | ||||||||||||
|
Bellows type |
twenty |
twenty-one |
twenty-five |
thirty |
thirty-three |
forty-eight |
seventy-one |
ninety-one |
one hundred and two |
one hundred and fifteen |
one hundred and forty-five | ||||||||||||
|
Low temperature type |
Weight increase of ordinary type (10-20)% | ||||||||||||||||||||||