Product name: HB series linear and right angled star delta conversion contactor
specification: HB series linear and right angled star delta conversion contactor
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- AC contactor
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


HB series linear and right angled star delta conversion contactorDetailed product description:Column tabs

HB series linear and right angled star delta conversion contactor wiring diagram

Linear installation
Installation method of HB series linear and right angle star delta conversion contactor

CJX2F
A
a
P
P1
P2
Q
f
s
Φ
b1
c
b
z
G
N
Y
X1
500V≤
>500V
F115
six hundred and thirty
five hundred and seventy-two
thirty-seven
seventy-eight
one hundred and fifty-two
sixty
one hundred and nine
fifteen
M6
one hundred and thirty-seven
one hundred and eighty-six
one hundred and sixty-two
seven
eighty
thirteen
two hundred
ten
fifteen
F150
six hundred and thirty
five hundred and seventy-nine
forty
seventy-two
one hundred and fifty-two
fifty-seven point five
one hundred and nine
twenty
M8
one hundred and thirty-seven
one hundred and eighty-six
one hundred and seventy
seven
eighty
thirteen
two hundred
ten
fifteen
F185
six hundred and thirty
five hundred and ninety-four
forty
seventy-eight
one hundred and fifty-eight
fifty-nine point five
one hundred and nineteen
twenty
M8
one hundred and thirty-seven
one hundred and ninety-six
one hundred and seventy-four
seven
eighty
thirteen
two hundred
ten
fifteen
F225
six hundred and thirty
six hundred and eleven
forty-eight
sixty-two
one hundred and fifty-eight
fifty-one point five
one hundred and nineteen
twenty-five
M10
one hundred and thirty-seven
one hundred and ninety-six
one hundred and ninety-seven
seven
eighty
thirteen
two hundred
ten
fifteen


HB series straight and right angled star delta conversion contactor right angled installation

Installation diagram of HB series linear and right angle star delta conversion contactor
Outline drawing of HB series linear and right angled star delta conversion contactor
Contact diagram of HB series linear and right angled star delta conversion contactor


Typical curve diagram of current and torque during starting of star delta contactor
Characteristic curves of HB series linear and right angled star delta conversion contactors

1. The starting current of a star connection is approximately 1.8-2.6 times the rated current of the motor.
2. The starting torque of the star connection is 1/3 of the direct starting torque of the triangle, which is 50% of the rated torque.
3. When the motor starts, it is connected in a star shape, and during normal operation, it is connected in a triangle shape. When starting, when the speed reaches 80% of the rated speed, the starter switches from a star connection to a delta connection.
4. The rated current for starting the HB series linear and right angled star delta conversion contactors is the rated current value when connected in a delta configuration, and the maximum controlled motor power is the controlled power when connected in a delta configuration.
5. The load when starting the motor with the Star Triangle starter belongs to the AC3 usage category.
6. The Star Triangle Starter is only suitable for three-phase motors with six stator terminals connected.
7. The Star Triangle Starter is used for starting motors without load or starting motors with small initial torque and gradually increasing torque.

Normal working conditions and installation conditions
1. The ambient air temperature ranges from -5 ℃ to 40 ℃, with an average value not exceeding+35 ℃ within 24 hours
2. Altitude: not exceeding 2000m, capacity can be reduced to 3000m.
3. Atmospheric conditions: At+40 ℃, the relative humidity of the atmosphere does not exceed 50%. At lower temperatures, there can be higher relative humidity. The monthly average lowest temperature of the wettest month does not exceed+25 ℃, and the monthly average maximum relative humidity of that month does not exceed 90%, taking into account the condensation of the product due to temperature changes.
4. Pollution level: Level 3
5. Installation category: Level III
6. Installation conditions: The inclination angle between the installation surface and the person perpendicular to it shall not exceed ± 5 °
7. Shock out: The product is installed and used in a location without significant shaking, impulse, or vibration.