参数名称 参数值 单位
额定电压 40.5 kV
额定电流 1600 A
额定频率 50 Hz
短时(1min)工频耐受电压 95 kV
雷电冲击耐受电压 185 kV
额定短路开断电流 20 kA
额定峰值耐受电流 50 kA
额定短路关合电流 50 kA
额定短时耐受电流 20 kA
额定短路持续时间 4 s
额定单个电容器组开断电流 630 A
额定背对背电容器组开断电流 400 A
额定操作顺序 O-0.3s-CO-180s-CO
额定短路开断电流次数 20
机械寿命 10000
触头自闭力 180±50 N
额定开距下的触头反力 300±50 N
额定触头压力下限时的回路电阻 25 μΩ
触头允许磨损厚度 3 mm
真空灭弧室内部气体压力 0.001 Pa
运动部分的质量 3.67 kg
真空灭弧室质量 12 kg
触头开距 22±2 mm
平均分闸速度 1.6±0.2 m/s
平均合闸速度 0.6±0.2 m/s
额定触头压力 2500±200 N
触头合闸弹跳时间 2 ms
触头合闸和分闸不同期性 2 ms
分闸触头反弹幅值 2 mm
外径 138 mm
安装高度 414 mm
外形 屏蔽筒外露

TD21-40.5/1600-20真空灭弧室
 

TD21-40.5/1600-20真空灭弧室