CLL series self-locking jackDetailed product description:Column tabs
1、 Application of self-locking jack
Self locking jacks are mainly used in places where heavy objects need to be supported for a long time. They can still support heavy objects even when the oil pressure is removed, and they are safe and reliable. It can be used underwater, single acting, load retraction, and nut self-locking to make the load safer. Especially in large projects, it is easy to operate and control and hydraulic jack. It is designed with a safety pressure protection device and a built-in pressure relief valve to prevent overload and protect the jack for safe operation. The connection of this device adopts high-pressure rubber hose and threaded joint connection, which has the advantages of fast use and overcomes the shortcomings of traditional joint oil leakage. It is mainly used for equipment installation, lifting and dismantling operations in various industries such as power, construction, machinery manufacturing, mining, railway bridges, shipbuilding, etc

2、 Basic parameters of self-locking jack: The parameters in the table may change due to improvements without prior notice.

model
tonnage
mm
itinerary
B-Amm
Body height
A mm
Extension height Bmm
outer diameter
mm
hydraulic cylinder
Area cm 2
Weight kg
CLL55-50
fifty-five
fifty
one hundred and sixty-four
two hundred and fourteen
one hundred and twenty-seven
seventy-one point three
sixteen
CLL55-100
one hundred
two hundred and fourteen
three hundred and fourteen
twenty-one
CLL55-150
one hundred and fifty
two hundred and sixty-four
four hundred and fourteen
twenty-six
CLL55-200
two hundred
three hundred and fourteen
five hundred and fourteen
thirty-one
CLL55-250
two hundred and fifty
three hundred and sixty-four
six hundred and fourteen
thirty-six
CLL55-300
three hundred
four hundred and fourteen
seven hundred and fourteen
forty-one
CLL100-50
one hundred
fifty
one hundred and eighty-seven
two hundred and thirty-seven
one hundred and fifty-five
one hundred and thirty-three point three
thirty-one
CLL100-100
one hundred
two hundred and thirty-seven
three hundred and thirty-seven
thirty-nine
CLL100-150
one hundred and fifty
two hundred and eighty-seven
four hundred and thirty-seven
forty-eight
CLL100-200
two hundred
three hundred and thirty-seven
five hundred and thirty-seven
fifty-seven
CLL100-250
two hundred and fifty
three hundred and eighty-seven
six hundred and thirty-seven
sixty-five
CLL100-300
three hundred
four hundred and thirty-seven
seven hundred and fifty-seven
seventy-four
CLL150-50
one hundred and fifty
fifty
one hundred and sixty-five
two hundred and fifteen
two hundred and nineteen
one hundred and ninety-eight
fifty-three
CLL150-100
one hundred
two hundred and fifteen
three hundred and fifteen
sixty-six
CLL150-150
one hundred and fifty
two hundred and sixty-five
four hundred and fifteen
seventy-eight
CLL150-200
two hundred
three hundred and fifteen
five hundred and fifteen
ninety-two
CLL150-250
two hundred and fifty
three hundred and sixty-five
six hundred and fifteen
one hundred and five
CLL150-300
three hundred
four hundred and fifteen
seven hundred and fifteen
one hundred and eighteen
CLL200-50
two hundred
fifty
one hundred and ninety-three
two hundred and forty-three
two hundred and forty-five
two hundred and sixty-six point five
eighty-three

CLL200-100

one hundred
two hundred and forty-three
three hundred and forty-three
one hundred and one
CLL200-150
one hundred and fifty
two hundred and ninety-three
four hundred and ninety-three
one hundred and eighteen

CLL200-200

two hundred
three hundred and forty-three
five hundred and forty-three
one hundred and thirty-six
CLL200-250
two hundred and fifty
three hundred and ninety-three
six hundred and forty-three
one hundred and fifty-three

CLL200-300

three hundred
four hundred and forty-three
seven hundred and forty-three
one hundred and seventy-one
CLL280-50
two hundred and eighty
fifty
two hundred and forty-nine
two hundred and ninety-nine
three hundred and twenty-five
three hundred and sixty-six point four
one hundred and sixteen

CLL280-100

one hundred
two hundred and ninety-nine
three hundred and ninety-nine
one hundred and forty
CLL280- 150
one hundred and fifty
three hundred and forty-nine
four hundred and ninety-nine
one hundred and sixty-three

CLL280-200

two hundred
three hundred and ninety-nine
five hundred and ninety-nine
one hundred and eighty-seven
CLL280-250
two hundred and fifty
four hundred and forty-nine
six hundred and ninety-nine
two hundred and ten

CLL280-300

three hundred
four hundred and ninety-nine
seven hundred and ninety-nine
two hundred and thirty-four
CLL350-50
three hundred and fifty
fifty
two hundred and ninety-five
three hundred and forty-five
three hundred and fifty-five
four hundred and fifty-seven
one hundred and seventy-three

CLL350-100

one hundred

three hundred and forty-five

four hundred and forty-five
two hundred and three
CLL350-150
one hundred and fifty
three hundred and ninety-five
five hundred and forty-five
two hundred and thirty-three

CLL350-200

two hundred

four hundred and forty-five

six hundred and forty-five
two hundred and sixty-three
CLL350-250
two hundred and fifty
four hundred and ninety-five
seven hundred and forty-five
two hundred and ninety-three

CLL350-300

three hundred

five hundred and forty-five

eight hundred and forty-five
three hundred and twenty-three
CLL430-50
four hundred and thirty
fifty
three hundred and thirty-five
three hundred and eighty-five
three hundred and eighty
five hundred and fifty-nine
two hundred and fifty-one

CLL430-100

one hundred
three hundred and eighty-five
four hundred and eighty-five
two hundred and eighty-nine
CLL430-150
one hundred and fifty
four hundred and thirty-five
five hundred and eighty-five
three hundred and twenty-seven

CLL430-200

two hundred
four hundred and eighty-five
six hundred and eighty-five
three hundred and sixty-five
CLL430-250
two hundred and fifty
five hundred and thirty-five
seven hundred and eighty-five
four hundred and three

CLL430-300

three hundred
five hundred and eighty-five
eight hundred and eighty-five
four hundred and forty-one
CLL565-50
five hundred and sixty-five
fifty
three hundred and seventy-five
four hundred and twenty-five
four hundred and thirty
seven hundred and thirty
three hundred and sixty-seven
CLL565-150
one hundred and fifty
four hundred and seventy-five
six hundred and twenty-five
four hundred and sixty-seven
CLL565-250
two hundred and fifty
five hundred and seventy-five
eight hundred and twenty-five
five hundred and sixty-eight


3、 How to use self-locking jack

1. When the oil level of the pump body is insufficient, it is necessary to add working oil (10 # engine oil) to the pump before it can work.
2. Estimate the lifting capacity and avoid overloading during use.
3. Determine the center of gravity of the lifting object, select the point of force for the jack, and consider whether the ground is soft or hard and whether it is cushioned with tough wood to avoid the risk of tipping during lifting.
4. After the jack lifts the heavy object, it should be supported firmly with tough wood in a timely manner. It is forbidden to use the jack as a support to avoid uneven load and the risk of tipping.
5. When using, first connect the quick connector of the manual pump to the top, then select the position and tighten the oil drain screw on the oil pump to start working. Loosen the oil drain screw and unload the oil cylinder.
6. Please refer to the instruction manual for electric pumps.

4、 Precautions for self-locking jack
a) If there is a phenomenon of empty tapping during use, you can first loosen the oil drain screw on the pump body, lift the pump body vertically and tap downwards a few times, then tighten the oil drain screw, and continue to use.
b) When there is a load, do not remove the quick connector to avoid accidents and damage to the components.
c) This machine uses oil as the medium, and it is necessary to maintain the oil and this equipment properly to avoid clogging or oil leakage, which may affect the effectiveness of use.
d) A new or long-term hydraulic jack may experience a slight jump in the piston rod when it is first used due to the presence of a large amount of air in the cylinder. The hydraulic jack can be moved back and forth 2-3 times without load to eliminate the air in the chamber. Long term idle hydraulic jacks, due to the hardening of seals caused by prolonged inactivity, affect the service life of hydraulic jacks. Therefore, when hydraulic jacks are not in use, they should be moved back and forth with no load 2-3 times a month.

CLL series self-locking jack
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference