HomeYour location:Homemotor productsasynchronous motorAC variable frequency motor → YVP2 series variable frequency speed regulation three-phase asynchronous motor
Column tabs 
Product name: YVP2 series variable frequency speed regulation three-phase asynchronous motor
specification: YVP2 series variable frequency speed regulation three-phase asynchronous motor
  Zoom Zoom in on the image
Category: motor products -- AC variable frequency motor
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13901609058(Wechat)


YVP2 series variable frequency speed regulation three-phase asynchronous motorDetailed product description:Column tabs
The YVP2 series variable frequency speed regulating three-phase asynchronous motor is a highly efficient and energy-saving AC speed regulating motor promoted as a key initiative in the national Ninth Five Year Plan. At low speeds (frequency 50HZ), it can operate with constant torque speed regulation within a range of 1:10 and run smoothly.

The YVP2 series variable frequency speed regulation three-phase asynchronous motor has high locked rotor torque and small locked rotor current. The electric motor can output constant power at high speed. Wide high-speed range, low vibration, low noise, can be matched with various SPWM frequency converters at home and abroad to form an AC frequency stepless speed regulation system. Energy saving of over 30% with significant effects. It can be widely used in industries such as spindle drive of CNC machine tools, textile, chemical, printing, plastics, metallurgy, etc. for constant torque and constant power speed, as well as energy-saving speed regulation of fans, water pumps, etc. It also has a computer control interface, which helps to achieve automatic control of speed regulation systems  

Usage conditions: Rated voltage 380V Frequency 50Hz Shell protection level IP54
Cooling method IC411 Work System S1 F-class insulation
Altitude not exceeding 1000m Environmental temperature -15--40 ℃
The average highest humidity in the wettest month is 90%, and the average lowest humidity in that month is not higher than 25 ℃

DMZ1 Technical Data

Rated power kw
2-pole
4-pole
6 poles
8 poles
frame size
Rated torque N-m
Current A
frame size
Rated torque N-m
Current A
frame size
Rated torque N-m
Current A
frame size
Rated torque N-m
Current A
zero point five five
eight hundred and one
three point five
one point eight
zero point seven five
eight hundred and one
two point four
one point eight
eight hundred and two
four point seven
two point three
90S
seven
two point five
one point one
eight hundred and two
three point six
two point seven
90S
seven
three
90L
ten point five
three point five
100L
fourteen
three point five
one point five
90S
four point nine
three point four
90L
nine point five
four point one
100L
fourteen
four point four
112M
nineteen
five
two point two
90L
seven
four point nine
100L1
fourteen
five point five
112M
twenty-one
six point one
132S
twenty-eight
six point four
three
100L
nine point six
six point four
100L2
nineteen
seven point five
132S
twenty-eight point five
seven point nine
132M
thirty-eight
eight point five
four
112M
thirteen
eight point two
112M
twenty-five
nine point six
132M1
thirty-seven point five
ten point three
160M1
fifty
ten point nine
five point five
132S1
seventeen point five
eleven point one
132S
thirty-five
twelve point seven
132M2
fifty-two point five
thirteen point eight
160M2
seventy
fourteen point six
seven point five
132S2
twenty-four
fifteen
132M
forty-seven point five
seventeen
160M
seventy-one
eighteen point seven
160L
ninety-five
nineteen point five
eleven
160M1
thirty-five
twenty-one point eight
160M
seventy
twenty-four point eight
160L
one hundred and five
twenty-seven
180M
one hundred and forty
twenty-six point four
fifteen
160M2
forty-eight point seven
twenty-nine point four
160L
ninety-five
thirty-three
180L
one hundred and forty-two point five
thirty-four point six
200L
one hundred and ninety
thirty-five point eight
eighteen point five
160L
fifty-eight point nine
thirty-eight point nine
180M
one hundred and seventeen point five
thirty-seven point seven
200L1
one hundred and seventy-six
thirty-nine point six
225S
two hundred and thirty-five
forty-three point four
twenty-two
180M
seventy-one point four
forty-four
180L
one hundred and forty
forty-four point five
200L2
two hundred and ten
forty-six point eight
225M
two hundred and eighty
fifty
thirty
200L1
ninety-seven point four
fifty-nine
200L
one hundred and ninety
fifty-nine point six
225M
two hundred and eighty-five point five
sixty-two point five
250M
three hundred and eighty-one
sixty-six
thirty-seven
200L2
one hundred and twenty
seventy-three
225S
two hundred and thirty-five
seventy-three point two
250M
three hundred and fifty-two point five
seventy-five point six
280S
four hundred and seventy
eighty-two point seven
forty-five
225M
one hundred and forty-six
eighty-seven
225M
two hundred and eighty-six
eighty-eight point four
280S
four hundred and twenty-nine
eighty-nine point six
280M
five hundred and seventy-two
ninety-seven point eight
fifty-five
250M
one hundred and seventy-eight
one hundred and seven
250M
three hundred and fifty
one hundred and seven point five
280M
five hundred and twenty-five
one hundred and ten
seventy-five
280S
two hundred and forty-three point four
one hundred and forty-six
280S
four hundred and forty-seven
one hundred and forty-six point six
ninety
280M
two hundred and ninety-two
one hundred and seventy-three
280M
five hundred and seventy-two point five
one hundred and seventy-two point five

YVP2 series variable frequency speed regulation three-phase asynchronous motor ordering instructions

To avoid unnecessary errors after ordering, it is advisable to inquire about detailed information as much as possible before placing an order, and verify it from all aspects and perspectives in order to select the most appropriate model.
·When placing an order, please specify the machine model based on the required power, output speed, input voltage, input frequency, installation form, etc. If a special motor is selected, please consult with our company.
·Please try to choose standard products from this catalog when placing an order. If there are any other special requirements, please provide detailed explanations before signing the contract.
·Our company can undertake orders for special specification products and provide professional design services to customers.
·If there are any improvements or changes in this sample, no further notice will be given

YVP2 series variable frequency speed regulation three-phase asynchronous motor
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference