DJ-100Q series voltage relayDetailed product description:Column tabs
1 Purpose
The DJ-100Q system voltage relay is used in relay protection device circuits as an action component for overvoltage protection or low voltage lockout.

2. Structure and Operating Principles
2.1 The DJ-LOOQ series voltage relay adopts embedded installation, and the main body of the relay is a plug-in structure.
The main body of the DJ-100Q series voltage relay is identical to that of the DJ-100 series voltage relay.
2.3 Relay system electromagnetic instantaneous action, magnetic system has two coils, the coil head is connected to the terminal of the relay base and the bottom terminal of the housing with a special connecting piece, which can connect the coils in series or parallel, thus doubling the setting range of the relay.
The internal wiring diagram of the DJ-100Q series voltage relay is shown in Figure 1.
The appearance and installation dimensions of the DJ-100Q series voltage relay are shown in Figure 2.

DJ-100Q series voltage relay contact diagram

DJ-111Q112Q DJ-121Q122Q DJ-131Q132Q DJ-131/60CQ DJ-131/60CNQ
Figure 1 Internal wiring diagram of DJ-100Q series voltage relay (back view)
Installation dimensions of DJ-100Q series voltage relay

Figure 2: Outline and Installation Dimensions of DJ-100Q Series Intermediate Relays

3 Technical Requirements
3.1 Disconnecting capacity of contacts: When the voltage is below 220V and the current is not greater than 2A, it is 50W in DC circuits with inductive loads (time constant T not greater than 5 × 10-3S); 250VA (COS Φ=0.4) in AC circuits.
3.2 Action time: For overvoltage relays, the action time should not exceed 0.12s at 1.1 times the set value, and 0.04s at 2 times the set value. When the low voltage relay is at 0.5 times the set value, the action time shall not exceed 0.15 seconds.
3.3 Dielectric Strength: The insulation of the outer shell of the conductive part of the relay should withstand a test of AC 50Hz, voltage 2kV, and duration of 1min.
The weight of the relay is approximately 1.5kg.
The technical data of the DJ-100Q series voltage relay is listed in the table.

model

Setting range

(V)

Long term allowable voltage (V)

Contact specifications

return coefficient

Power consumption (at minimum set voltage) (VA)

remark

Coil series connection

Parallel connection of coils

Dynamic combination

Dynamic interruption

DJ—11lQ

15~60

50~200

100~400

seventy

two hundred and twenty

four hundred and forty

thirty-five

one hundred and ten

two hundred and twenty

one

0.8

one

overvoltage

relay

DJ—12lQ

15~60

50~200

100~400

seventy

two hundred and twenty

four hundred and forty

thirty-five

one hundred and ten

two hundred and twenty

l

DJ—13lQ

15~60

50~200

100~400

seventy

two hundred and twenty

four hundred and forty

thirty-five

one hundred and ten

two hundred and twenty

one

one

DJ—131Q/60C

15~60

two hundred and twenty

one hundred and ten

one

one

l.5

DJ—112Q

12~48

40~160

80~320

seventy

two hundred and twenty

four hundred and forty

thirty-five

one hundred and ten

two hundred and twenty

one

one point two five

one

low voltage

relay



4 Ordering Instructions
4.1 Model and name of relay.
4.2 Maximum setting value (current or voltage).
4.3 Number of relays.
DJ-100Q series voltage relay(No image available)