Product name: RXMA1 type intermediate relay
specification: RXMA1 type intermediate relay
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- intermediate relay
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


RXMA1 type intermediate relayDetailed product description:Column tabs
The RXMA1 intermediate relay is used in power system secondary circuits and industrial automation control circuits as an intermediate auxiliary to expand control circuits.

2 Structural Features
2.1 It can provide up to 7 pairs of dynamic closing or breaking and conversion contacts, with a compact structure.
2.2 The contact action can be tested by moving the armature through the small hole on the cover.
2.3 There are two types of coil excitation: AC and DC.

3 Principles of Action
The RXMAl intermediate relay is an electromagnetic snap on structure, consisting of an electromagnetic system and a contact system. When the coil is powered on, a magnetic field is generated by the iron core to attract the suction plate, which drives the spring to switch the contact circuit. The contact adopts dual contact, which has the advantages of low contact resistance, strong contact reliability, and large breaking load capacity. The inertia of the absorber design is very small, so this relay can withstand a certain amount of shock and vibration, and can withstand the impact of moderate seismic waves. The relay housing adopts the imported Combiflex structure.

Technical data of RXMA1 intermediate relay

4.1 Operating voltage: D.C.<70% of rated voltage.
4.2 Return voltage: D.C.>5% rated voltage.
4.3 Action time: The contact point for moving and closing should not exceed 40ms, and the contact point for moving and breaking should not exceed 30ms.
4.4 Coil power consumption:<2W
4.5 Contact points are allowed to pass 5A current for a long time
When the time for passing current is less than 200ms, 90A current is allowed to pass through;
When the time for passing current is 1 second, it is allowed to pass 50A current.
4.6 Contact breaking capacity: A.C.: 5A at 250V (power factor>0.4), 250VA
D. C. At 250V, it is 2A (L/R=40ms) and 45W.

When the voltage is 24V (DC)

4A/6A (single contact)/(double contact series)

When the voltage is 48V (DC)

1.5A/4A (single contact)/(double contact series)

When the voltage is 55V (DC)

1.0A/2.5A (single contact)/(double contact series)

When the voltage is 110V (DC)

0.4A/1.0A (single contact)/(double contact series)

When the voltage is 125V (DC)

0.3A/0.7A (single contact)/(double contact series)

When the voltage is 220V (DC)

0.2A/0.4A (single contact)/(double contact series)

When the voltage is 250V (DC)

0.15A/0.3A (single contact)/(double contact series)


4.7 Insulation withstand voltage: 50Hz, 1min, 2kY.
4.8 Impulse voltage: 5kV.
4.9 Can withstand seismic waves with a moderate magnitude of 5-15Hz.
4.10 Rated voltage and coil resistance. (See Tables 2 and 3)

Voltage level DC (V)

six

twelve

twenty-four

thirty-six

forty-eight

fifty-five

one hundred and ten

two hundred and twenty

Coil resistance value (Ω)

twenty-nine

one hundred and fifteen

four hundred and sixty

1.15k

2.02k

2.6k

9.68k

39.2k


Voltage level AC (V)

twenty-four

forty-eight

one hundred and ten

two hundred and twenty

Coil resistance value (Ω)

one hundred and fifteen

four hundred and sixty

2.02k

9.68k


4.11 Contact specifications


RK211 063 RK211 064 RK211 066 RK211 072

RXMA1 type intermediate relay contact diagram 1

RK211 073 RK211 074 RK211 025 RK211 037

RXMA1 type intermediate relay contact diagram 2

RK211 052 RK211 070 RK211 071 RK211 075

RXMA1 type intermediate relay contact diagram 3

RK211 076 RK211 077 RK211 078 RK211 079

RXMA1 type intermediate relay contact diagram 4



4.12 External dimensions of protruding modular insertion structureAppendix IIIAttached Figure I (2S6C).
4.13 Installation dimensions of protruding modular insertion structure according toAppendix IIIIn Figure 5 (2S6C), 2 can be inserted side by side according to Figure 6 (2S12C), 2 can be inserted straight according to Figure 7 (4S6C), and 4 can be inserted according to Figure 8 (4S12C).

5 Ordering Instructions
Please indicate the model, contact code, and voltage level when placing an order. AC specifications can be provided.
Example: RXMAl RK211063-DC2220V.

RXMA1 type intermediate relay
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference