| Product name: | RXMH2 type large capacity intermediate relay | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- intermediate relay | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
2 Characteristics
2.1 The number of contacts can reach up to 8, with a large breaking capacity.
2.2 Coil excitation is divided into two types: DC and AC.
3 Action principles:
The RXMH2 high-capacity intermediate relay is an electromagnetic relay. It consists of three parts: electromagnetic system, contact system, and bracket. The electromagnetic system adopts a direct acting structure with a large working stroke. The contact system adopts bridge contacts with large breaking capacity. When the coil is energized, it generates a magnetic field that attracts the iron core. The contact conversion is driven by the iron core. The shell adopts a Combiflex protruding modular insertion structure with bow I insertion.
Technical data of RXMH2 large capacity intermediate relay
4.1 Operating voltage: DC.<70% of rated voltage; AC<85% rated voltage.
4.2 Return voltage: DC.>5% rated voltage; AC>15% rated voltage.
4.3 Action time:<55ms RK223 070 specification<60ms, AC specification<65ms.
4.4 Coil power consumption: D.C. is 5.5W; A.C. is 9VA
4.5 Maximum breaking capacity of contacts: A.C. V ≯ 250V; I ≯ 10A (power factor of 0.4 ± 0.1) is 1000VA
D.C. V≯250V; I ≯ 5A, (L/R=40ms) is 100W
If the contact breaking capacity is increased, the contacts can be connected in series according to the data in Table 1.
|
When the voltage (DC) is 55V |
20A/20A (single contact)/(double contact series) |
|
When the voltage (DC) is 110V |
6A/20A (single contact)/(double contact series) |
|
When the voltage (DC) is 125V |
5A/20A (single contact)/(double contact series) |
|
When the voltage (DC) is 220V |
1.2A/6A (single contact)/(double contact series) |
|
When the voltage (DC) is 250V |
1A/5A (single contact)/(double contact series) |
4.6 Insulation withstand voltage: 50Hz, 1min, 2kV.
4.7 Impulse voltage: 5kV.
4.8 Can withstand seismic waves with a moderate magnitude of 5-15Hz.
4.9 Rated voltage and coil resistance. (See Tables 2 and 3)
|
Voltage level DC (V) |
twelve |
twenty-four |
thirty-six |
forty-eight |
fifty-five |
sixty |
sixty-eight |
one hundred and ten |
one hundred and twenty-five |
two hundred and twenty |
two hundred and fifty | ||||||||||
|
Coil resistance value |
thirty-nine point five |
one hundred and fifty-five |
two hundred and ninety-seven |
five hundred and sixty-four |
seven hundred and one |
eight hundred and ninety |
1.15k |
2.93k |
3.61k |
10.6k |
13.5k | ||||||||||
|
Voltage level AC (V) |
twenty-four |
twenty-nine |
fifty-five |
one hundred and fifteen |
one hundred and ten |
one hundred and twenty |
one hundred and twenty-seven |
two hundred and twenty |
two hundred and thirty |
three hundred and eighty | |||||||||||
|
Coil resistance value |
thirty-nine point five |
fifty |
one hundred and ninety-four |
eight hundred and ninety |
seven hundred and one |
nine hundred and forty-eight |
eight hundred and ninety |
2.93k |
3.61k |
8.52k |
4.10 RXMH2 large capacity intermediate relay contact specifications (see Table 4)
| ||||
![]() |
4.11 The external dimensions of the protruding modular insertion structure are shown inAppendix IIIAttached Figure 2 (2S12C).
4.12 The installation dimensions and opening dimensions of the protruding modular insertion structure base are shown inAppendix IIIAttached Figure 6 (2S12C).
5 Ordering Instructions
Please indicate the model, contact code, and voltage level when placing an order.
Example: RXMH2 RK223067-DC2220V.