| Product name: | 0.1 high-precision 0.1 programmable 81 segment PID regulator | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- industrial control equipment | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
model |
technical performance | ||||||
|
FP21 |
9 sets of 9-segment programmable regulators, PID automatic tuning, high-precision 0.1% FS ± 1 word, DIN 96 × 96 × 140mm, 9 sets of PID and 9 sets of amplitude limiting, servo starting, ensuring platform, with LCD screen curve and status display, convenient external switch quantity for operation, three PID algorithms, with 4 sets of sequential control time scales. The basic configuration includes three time scales and two upper/lower limit alarm relays, 10 isolated outputs, and 8 isolated inputs | ||||||
|
input |
one |
Thermocouple type, 15 types of thermocouples to choose from, temperature range -200~2300 ℃ | |||||
|
two |
Platinum resistance type (Pt100): 8 optional ranges, temperature range -200~600 ℃ | ||||||
|
three |
DC voltage type: Users can choose from 0 to 10; 0~20; 0~50; 0~100; 10~50; -10~+10mV | ||||||
|
four |
DC current type: Users can choose 4-20, 0-20mA linear input | ||||||
|
six |
DC voltage type: Users can choose 0-1, 0-2, 0-5, 0-10, 1-5, -1 to+1V DC linear input | ||||||
|
isolation control output |
Y |
Relay contact: Time proportional cycle 1-120 seconds, 240V AC 2.5A/pure resistance, 1A inductive | |||||
|
I |
Current output: 4-20mA DC, load resistance=600 Ω/maximum | ||||||
|
P |
Solid state relay (SSR) output: Time proportional cycle 1-120 seconds, 15V DC/20mA maximum | ||||||
|
V |
Voltage output: 0-10V DC, load current=2mA/maximum | ||||||
|
Isolation module Proposed to send (Set PV or SV values inside the machine) |
00 |
nothing | |||||
|
thirteen |
0-10mV DC output impedance 10 Ω |
Single output | |||||
|
fourteen |
4-20mA DC load resistance=500 Ω/maximum | ||||||
|
sixteen |
0-10V DC load current=2mA/maximum | ||||||
|
twenty-three |
0-10mV DC output impedance 10 Ω |
dual output | |||||
|
twenty-four |
4-20mA DC load resistance=500 Ω/maximum | ||||||
|
twenty-six |
0-10V DC load current=2mA/maximum | ||||||
|
communication interface |
0 |
nothing | |||||
|
six |
RS-422A communication distance is 1.2 kilometers (one link can control 10 units) | ||||||
|
seven |
RS-232C, Communication distance of 15 meters (point-to-point) | ||||||
|
External I/O |
0 |
24 pin plug | |||||
FP21 high-precision 0.1 level programmable 81 segment PID regulator