HomeYour location:HomeHigh voltage electrical appliancesHigh voltage protectorfault indicator → Z1-SE Short circuit grounding 2 Combined with 1 fault indicator
Column tabs 
Product name: Z1-SE Short circuit grounding 2 Combined with 1 fault indicator
specification: Z1-SE Short circuit grounding 2 Combined with 1 fault indicator
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- fault indicator
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


Z1-SE Short circuit grounding 2 Combined with 1 fault indicatorDetailed product description:Column tabs

Z1-SE Short Circuit Grounding 2-in-1 Fault Indicator Product Function and Features

Display mode: daytime flip card display, night vision reflection within 360 º ○ range can be observed.
Identifying faults has the function of identifying ground short circuit faults, and can distinguish between permanent faults and transient faults.
Fault diagnosis can only be given in the event of a ground short circuit fault, sudden change in current, and after the switch trips, without the need to set action values.
When suppressing the surge current during power transmission, the indicator detects the excitation current and locks the circuit to prevent the fault indicator from malfunctioning.
Online operation is directly installed on power lines (overhead lines or busbars) and can operate outdoors for a long time without maintenance.
Special tools for live loading and unloading applications can be installed and removed with electricity, and there will be no false alarms during the loading and unloading process.
The night vision reflective display board adopts night vision reflective technology for easy observation at night.
Rust resistant and corrosion-resistant structural components are made of rust resistant and corrosion-resistant materials

2、 Schematic diagram of grounding short circuit of overhead line
Short circuit detection: As shown in the figure, when a short circuit fault occurs in the circuit, the short circuit fault indicator senses the fault current, and the display window of the indicator will change from white to red (or from no light to light). Based on the fact that the B-phase indicators 2, 5, 8 on Line 2 and the C-phase indicators 3, 6, and 9 on Line 3 have flipped over (or lit up), while the indicators 11 and 12 have not flipped over (or lit up), it can be quickly determined that the fault is at point D.

Grounding detection principle: Grounding detection principle: Sample the first half wave of the capacitance current at the moment of grounding and the first half wave of the voltage at the moment of grounding, compare their phases. When the capacitance current at the moment of sampling grounding suddenly changes and exceeds a certain value, and is in phase with the first half wave of the voltage at the moment of grounding, and the wire to ground voltage decreases at the same time, it is judged that the line has been grounded. Otherwise, the line has not been grounded. As shown in the figure, if the indicators 3, 6, and 9 of phase C on line 2 flip over and the indicator 12 still does not move, it can be determined that a grounding fault has occurred at point D.

3、 Z1-SE short-circuit grounding 2-in-1 fault indicator action criterion
(1) It ≥ 160A. It is the starting value of the sudden variable current
(2) △ I ≥ 0.5I0 △ I is the current change rate I0 is the line current before the short circuit
(3) I=0, I is the current after the line fault
(4) 0.06S ≤ △ T ≤ 3S △ T is the sudden change time of current

4、 Z1-SE Short Circuit Grounding 2-in-1 Fault Indicator Technical Parameters
Applicable voltage: 6-35kV, parameters may vary for different voltage levels
Load current 0-1200A
Applicable wire outer diameter 25 mm2-400 mm2
The default factory setting for fault reset time is 12h and 24h (can also be adjusted according to user requirements)
Applicable ambient temperature -35 ℃~75 ℃
Capable of performing actions ≥ 5000 times
Weight ≤ 500g
Battery life>10 years
Device service life>10 years
Wind resistance capacity: wind speed of 150km/h, cannot be loosened

5、 Loading and unloading of Z1-SE short-circuit grounding 2-in-1 fault indicator
For short-circuit fault indicators installed on overhead lines, specialized installation tools can be used for live installation and disassembly. Installation instructions for Z1-SEII overhead short-circuit grounding four in one fault indicator.

Z1-SE Short Circuit Grounding 2-in-1 Fault Indicator Electrical Schematic Diagram

Z1-SE Short circuit grounding 2 Combined with 1 fault indicator