Application and scope of CXM series marine sealed transformers
The CXM series transformers are suitable for AC voltages below 500V in the shipbuilding industry; For control circuit indicators and local lighting with a frequency of 50Hz-60Hz, the enclosure protection level is IP20. The transformer can operate normally under the following environmental conditions:
a. The ambient temperature is -25-50 ℃;
b. The relative humidity of the air is not greater than 95%
c. The effects of condensation mist, oil mist, salt mist, and mold are present. D. Vibration and impact are generated during the operation of ships; e. The swaying angle of the ship during operation is 22.50 °, and the tilting angle is 150 °.
The CXM series marine sealed transformer meets the following standards
1. China Shipbuilding Industry Standard CB/T 1167-92
2. The regulations of the Ship Inspection Bureau of the People's Republic of China, "Test Regulations for Ship Electrical and Electronic Products," 1994, were commissioned by the Nanjing Ship Inspection Bureau and passed the type test at the 723 Testing Center. The product nameplate standard is recognized to have CCS ship inspection marks.
Model, specifications and main parameters
|
model |
Rated capacity (VA) |
Primary rated voltage 50-60Hz |
Secondary rated voltage 50-60Hz |
|
CXM-50 |
fifty |
220-480v |
6-440v |
|
CXM-100 |
one hundred |
|
CXM-160 |
one hundred and sixty |
|
CXM-250 |
two hundred and fifty |
|
CXM-400 |
four hundred |
|
CXM-500 |
five hundred |
|
CXM-630 |
six hundred and thirty |
The transformer operates continuously, and its rated parameters are shown in the table
Note: 1. The primary rated voltage and secondary rated voltage can be combined arbitrarily according to user needs; Various step-up transformers can be assembled as needed.
2. The allocation of rated output capacity at each secondary rated voltage shall be determined according to user requirements.
The main technical data is shown in the table
|
model |
power frequency Hz |
load voltage V |
Voltage regulation rate % |
efficiency % |
No load loss W |
insulation class |
|
CXM-50 |
50-60 |
6-440 |
≤5% |
eighty-four |
five |
B |
|
CXM-100 |
eighty-five |
twelve |
|
CXM-160 |
eighty-five |
fourteen |
|
CXM-250 |
eighty-six |
sixteen |
|
CXM-400 |
ninety |
twenty-two |
|
CXM-500 |
ninety-two |
twenty-three |
|
CXM-630 |
ninety-two |
twenty-five |