HomeYour location:Homeinstrumentation and metersElectrical instrumentsbridge → QJ47 portable DC single double arm bridge
Column tabs 
Product name: QJ47 portable DC single double arm bridge
specification: QJ47 portable DC single double arm bridge
  Zoom Zoom in on the image
Category: instrumentation and meters -- bridge
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13901609058(Wechat)


QJ47 portable DC single double arm bridgeDetailed product description:Column tabs
QJ47 portable DC single double arm bridge

1. Purpose:
The QJ47 portable DC single and double arm bridge is a portable precision DC single and double arm dual-use bridge (hereinafter referred to as single bridge and double bridge), suitable for on-site precision measurement of various metal conductors and various switch contact resistances in industrial and mining enterprises
2,
2.1: Accuracy level: 0.05 level
2.2: Measurement range: 10-3-106 ohms
2.3 The nominal range limits and allowable variations are shown in Table 1

impact quantity
Grade index
Nominal usage limit range
Permitted variation
effective range
ten-2---10fiveEurope
effective range
tenfive---10sixEurope
effective range
ten-3---10-2Europe
ambient temperature
0.05%
Reference value ± 10 ℃
100%
0.2%
Reference value ± 15 ℃
Reference value ± 18 ℃
relative humidity
All levels
25---80%
20%
power supply voltage
All levels
Rated value+15%
-17%
10%

Note: The nominal range of use for a single bridge is 105____. At 106, an additional power supply of 4.5__ volts is required


2.4 Basic Error Formula: Elim=5 × 10-4 (__RN+X)
In the formula: Allowable error limit of Elim__ (in ohms)
RN____ benchmark value (Euro)
X______ dial indication (Euro)
2.5 Reference conditions and allowable error indication for determining basic error

impact quantity
Reference conditions and tolerances
Single bridge
effective range
Grade index%
ambient temperature
20±2℃
ten__tenfive
zero point zero five
20±5℃
ten__tenfive
zero point two
Double bridge
Effective range (in ohms)
Grade index%
20±2℃
ten-2__tentwo
zero point zero five
20±5℃
ten-3__ten-23
zero point two
relative humidity
forty___70%
power supply voltage
Single bridge (internal) 1.5 volts: Double bridge (external) 1.5 volts__2 volts or 2.5A
Single bridge effective range 105___-tensixEuro time, requires 4.5 connections___6 volts

3. Power supply voltage
3.1 Single bridge: Two 1.5-volt No.1 batteries (internal), single, dual bridge shared
3.2 Dual Bridge: When the S-disk is set to ≤ 0.1, an external 2-volt power supply or 2.5A cross current source is required. If testing requirements are not high, a 1.5-volt A battery (external) can also be used
3.3 Amplifier Power Supply __9 Stacked Battery Section
4: Under the conditions of 2.3, the insulation strength between the metal components that can be in contact with the circuit and the casing should be able to withstand a frequency of 50 Hz, an actual sine wave AC voltage of 500 volts, and a duration of one minute
Under the conditions of 2.3, the insulation resistance between the metal components that can be in contact with the circuit and the casing is ≥ 2000 megaohms
6. Usage location:
7 Dimensions: 340 × 240 × 135Mmm
8 Weight:<5 kilograms

QJ47 portable DC single double arm bridge
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference