| Product name: | VSM1200DP Series Hall Voltage Sensor | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- voltage sensor | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
Electrical parameters | ||||||||
|
model |
VSM100DP |
VSM200DP |
VSM400DP |
VSM800DP |
VSM1000DP |
VSM1200DP |
||
|
VPN |
Primary rated input voltage |
one hundred |
two hundred |
four hundred |
eight hundred |
one thousand |
one thousand and two hundred |
V |
|
VP |
Measurement range of primary voltage |
0~±150 |
0~±300 |
0~±600 |
0~±1200 |
0~±1500 |
0~±1500 |
V |
|
VOUT |
Rated output voltage on the secondary side |
4±1% |
V | |||||
|
VC |
power supply voltage |
±15(±5%) |
V | |||||
|
IC |
Current consumption |
thirty |
mA | |||||
|
Vd |
insulation voltage |
3KV effective value/50Hz/1 minute between the primary and secondary circuits |
||||||
|
εL |
linearity |
<0.2 |
%FS | |||||
|
V0 |
Zero offset voltage |
TA=25℃ <±25 |
mV | |||||
|
VOT |
Unbalanced voltage temperature drift |
VP=0 TA=-25~+85℃ <±1 |
mV/℃ | |||||
|
Tr |
response time |
<100 |
us | |||||
|
TA |
Working environment temperature |
-25~+85 |
℃ | |||||
|
TS |
Storage environment temperature |
-40~+100 |
℃ | |||||
|
standard |
Q/320115QHKJ01-2010 | |||||||
Pin description: 1.+15V 2. -15V 3. Vout 4. 0V (power ground) OFS, zero adjustment GIN, amplitude adjustment
Instructions for Use
1. Incorrect wiring of sensors may result in module damage. After the sensor is powered on, when the measured voltage is connected from the input terminal of the sensor, the in-phase voltage value can be measured at the output terminal.
2. The output amplitude of the sensor can be adjusted appropriately according to user needs.