Product name: DZ12 series plastic shell circuit breaker
specification: 1P 2P 3P/6 10 16 20 32 40 50 63A DZ12 series plastic shell circuit breaker
  Zoom Zoom in on the image
Category: low-voltage electrical apparatus -- Miniature Circuit Breaker
Column tabs 
Price: factory price
Brand: 天正
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


DZ12 series plastic shell circuit breakerDetailed product description:Column tabs
1、 Scope of application
The DZ12 series plastic shell circuit breaker (hereinafter referred to as the circuit breaker) is suitable for AC 50Hz, rated current up to 63A, single-phase 230V and three-phase 400V circuits. It is mainly used for overload and short circuit protection of lighting lines, as well as for infrequent line switching under normal circumstances.  
The product complies with GB 10963 and IEC 60898-1 standards.  

2、 Model and its meaning
Model Description of DZ12 Series Plastic Shell Circuit Breaker
3、 Normal working conditions and installation conditions
1. The upper limit of the surrounding air temperature shall not exceed+40 ℃, the lower limit shall not be lower than -5 ℃, and the average temperature value over 24 hours shall not exceed+35 ℃;  
Note 1: For working conditions with a lower limit of -10 ℃ or -25 ℃, users must declare it to the manufacturer when placing an order;  
Note 2: For working conditions where the upper limit value exceeds+40 ℃ or the lower limit value is below -25 ℃, the user should consult with the manufacturer.  
2. The altitude of the installation site shall not exceed 2000m
3. The relative humidity of the atmosphere should not exceed 50% when the ambient air temperature is+40 ℃. Higher relative humidity is allowed at lower temperatures, such as reaching 90% at+20 ℃. Appropriate measures should be taken for occasional condensation caused by temperature changes;  
4. Pollution level: Level 2;  
5. Installation category: Class II and Class III;  
6. The external magnetic field of the installation site should not exceed 5 times the geomagnetic field in any direction;  
7. Generally installed vertically, with a tolerance of 2 ° in any direction;  
8. The installation site should have no significant impact or vibration.  
4、 Structural features
1. This circuit breaker consists of a handle, an operating mechanism, a trip device, an arc extinguishing device, and a contact system, all of which are installed in a plastic casing to form a single unit. Due to its ability to quickly open and close during operation, the contact wear is minimal and the lifespan is long.  
2. The release device has been adjusted and sealed before leaving the factory, so there is no need to worry about unexpected changes affecting the release characteristics.  
3. Two pole and three pole circuit breakers are equipped with interlocking trip devices inside, which will not cause single-phase power failure accidents.  

5、 Main technical parameters

Technical parameters of DZ12 series plastic shell circuit breaker

6、 DZ12 series plastic shell circuit breaker appearance and installation dimensions
Installation dimensions of DZ12 series plastic shell circuit breaker
7、 Ordering Notice
Users must specify the following when placing an order:
a、 Model and name of the circuit breaker;  
b、 Rated current of circuit breaker;  
c、 Extreme number;  
d、 quantity  
For example: DZ12-63, 2-pole, rated current 20A, 100 units.  
It should be written as: DZ12-63/2P 20A 100 units.