HomeYour location:Homeinstrumentation and metersElectrical instrumentsbridge → ZY4 Double arm bridge calibration standard
Column tabs 
Product name: ZY4 Double arm bridge calibration standard
specification: ZY4 Double arm bridge calibration standard
  Zoom Zoom in on the image
Category: instrumentation and meters -- bridge
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13901609058(Wechat)


ZY4 Double arm bridge calibration standardDetailed product description:Column tabs
ZY4 type double arm bridge calibration standard

Description
The ZY4 double bridge calibration standard is mainly used to make up for the shortcomings of the current high-precision adjustable standard, and to provide a practical combination standard for double bridge users, measurement stations, or maintenance centers who lack calibration standards. The entire instrument consists of two independent systems, namely the zeroing system and the standard resistance system, which can be used together or separately. Used as a standard or calibration device for the overall calibration of double bridges at levels below 0.05%, and can also be used as a zero point indicator for balancing circuits and for maintenance and sensitivity comparison of portable bridge zero point indicators
Main technical performance
1. Main parameters of each standard resistor (see table)
2. Zero point instrument system:
Voltage sensitivity is about 1.2 grids/μ V (approximately 1.4mm per grid)
Damping time:<4s
Indicator: ± 25 μ A (internal resistance of approximately 4k Ω, level 1.5, ± 50 division band)
Reflective mirror)
3. Zero pointer power supply: 1 6F22 type 9V laminated battery
4. Dimensions: 435 × 225x150 (mm)
5. Quality: Approximately 5kg
This instrument has eight fixed value standard resistors and three sets of stepper resistor sockets. According to the requirements of the standard instrument for 0.05% double bridge calibration. The highest accuracy is 0.01%. The accuracy decreases below 0.01 Ω, and the pattern of decrease is consistent with the decrease in accuracy of the double bridge in different measurement ranges.

Main parameters of each standard resistor

fixed
value
mark
accurate
electricity
block
resistance value
(Ω)
accuracy
(%)
reference power
(Current)
Short term maximum power
(Current)
Usage environment
temperature
Usage environment
relative humidity

one thousand

zero point zero one 0.05W 0.2W

20±15℃

Double bridge calibration temperature:

(1)0.05%

20±2℃

(2) 0.1%

20±10℃

(3) Below 0.1%

20±15℃

≤80%

one hundred

ten

one

ten-1

0.5A 1A

ten-2

zero point zero two 1.5A 2.5A

ten-3

zero point zero five 3.5A 6A

ten-4

zero point one
variable
standard
resistance

11×10

zero point zero one 0.05W 0.2W

11×1

11×10-1

zero point zero two


ZY4 type double arm bridge calibration standard

ZY4 Double arm bridge calibration standard