M-NZM series plastic shell circuit breakerDetailed product description:Column tabs
Purpose and Scope of Application
The M-NZM series plastic shell circuit breaker (hereinafter referred to as the circuit breaker) is one of the new circuit breakers developed and researched by our company using international advanced design and manufacturing technology. Its rated insulation voltage is 800V (M-NZM1-63 is 500V), suitable for circuits with AC 50Hz, rated working voltage below 690V (M-NZM1-63 is 400V), and rated working current up to 800A for infrequent switching and motor starting. Circuit breakers have overload, short circuit, and undervoltage protection functions, which can protect circuits and power equipment from damage.
Circuit breakers are classified into three types based on their rated ultimate short-circuit breaking capacity (LCU): N-type (standard type), H-type (higher breaking type), and L-type (high breaking type). This circuit breaker has the advantages of small size, high breaking height, short arcing (some specifications have zero arcing), and anti vibration, making it an ideal product for land and ship use.

Model and meaning of M-NZM series plastic shell circuit breaker

Model Description of M-NZM Series Plastic Shell Circuit Breaker
Note:
1) Circuit breakers for power distribution have no code; The circuit breaker for protecting the motor is represented by 2.
2) The handle can be operated directly without a code; Electric operation is represented by P; Rotate the handle and use Z to indicate.
Applicable working environment
Altitude of 2000m and below;
The temperature of the surrounding medium should not exceed+40oC (+45oC for marine products)
And not less than -5oC;
Can withstand the influence of humid air;
Capable of withstanding the effects of salt spray and oil spray;
The maximum tilt is ± 25.5o;
Can work reliably under normal ship vibration;
Can work reliably under earthquake conditions (4g);
In non explosive media, there is no medium that can corrode metals
Places where insulating gases and conductive dust are damaged;
In a place without rain or snow invasion.

Classification of M-NZM series plastic shell circuit breakers

Selection Table for M-NZM Series Plastic Shell Circuit Breakers
Release mechanism and accessory code
M-NZM series plastic shell circuit breaker accessory 1

Release mechanism and internal accessory code

M-NZM series plastic shell circuit breaker accessory 2

Note:
200: Refers to the circuit breaker body with only electromagnetic release; 300: Refers to a circuit breaker body with a thermal electromagnetic release; 000: The body of a circuit breaker without a release.
For M-NZM2-100 and M-NZM3-225 bipolar products, only 210, 310, 220, 320, 230, and 330 are available; M-NZM2-100, M-NZM3-160, 225 quadrupole
Circuit breakers without 218, 318, 248, 348, and without 240, 340, 260, 360, 268, 368 when the N pole is of type A and D;
The auxiliary contacts in specifications 248, 348, 278, and 378 of M-NZM4-400, M-NZM6-630, and M-NZM6-800 are a pair of contacts (i.e., one normally open and one normally closed),
The auxiliary contacts in specifications 268 and 368 are three pairs of contacts (i.e. three normally open and three normally closed).

The cross-sectional area of the connecting wire and the corresponding rated current

Rated current value (A)
ten
16,20
twenty-five
thirty-two
40,50
sixty-three
eighty
one hundred
one hundred and twenty-five
one hundred and sixty
18,200,225
two hundred and fifty
315,350
four hundred
Wire cross-sectional area (mm)two
one point five
two point five
four
six
ten
sixteen
twenty-five
thirty-five
fifty
seventy
ninety-five
one hundred and twenty
one hundred and eighty
two hundred and forty

Rated current value (A)
Cable
Copper bar
Cross sectional area (mm)two
quantity
Size (mm x mm)
quantity
five hundred
one hundred and fifty
two
30x5
two
six hundred and thirty
one hundred and eighty-five
two
40x5
two
700,800
two hundred
two
40x5
two

Internal and external attachments
Internal accessories of circuit breaker
According to the user's needs, the circuit breaker accessories can be directly wired or equipped with wiring terminals.
1. Undervoltage release device
There are three types of undervoltage release devices:
Type A: One specification with five voltage levels: AC50Hz 110V 230V 400V;
DC 110V 220V
Type B: (three-phase protection) One specification: AC50Hz 400V
Type C: Two specifications: AC50Hz 230V or 400V
Wiring diagram (internal accessories of the switch are shown in the dashed box)
M-NZM series plastic shell circuit breaker wiring diagram 1
M-NZM series plastic shell circuit breaker wiring diagram 2

When the rated working voltage is 70%~35%, the undervoltage release should reliably trip the circuit breaker. Warning: The undervoltage release must be powered on before the circuit breaker can be tripped and closed. Otherwise, it will damage the circuit breaker!

Rated current value (A)
Undervoltage release power (W)
AC230V
AC400V
M-NZM1-63
three point five
three point three
M-NZM2-100
two point six
three point three
M-NZM3-160
three point eight
three point three
M-NZM3-225
three point eight
three point three
M-NZM4-400
three point seven
two point seven
M-NZM5-630
two point three
two point seven
M-NZM6-800
two point five
two point eight


2. Split release device
Wiring diagram (dashed box shows internal attachments for production)

M-NZM series plastic shell circuit breaker wiring diagram 3

K: The normally closed contact of the micro switch connected in series with the coil inside the shunt release is automatically disconnected when the circuit breaker is opened and closed when it is closed.

3. Alarm contact

The position of the circuit breaker when it is in the "open" and "close" positions

M-NZM series plastic shell circuit breaker wiring diagram 4

The position of the circuit breaker when it is in "automatic trip" (alarm) mode

M-NZM series plastic shell circuit breaker wiring diagram 5

Specifications: AC50Hz, 230V or 400V; DC220V or 24V (note: DC24V is not recommended).
When the rated control power supply voltage is between 70-110%, the shunt release should reliably trip the circuit breaker.

4. Auxiliary contacts

The circuit breaker is in the "open" position

M-NZM series plastic shell circuit breaker wiring diagram 6

Circuit breakers with a current rating of 400A or higher on the shell frame (one set of four pairs of contacts)

M-NZM series plastic shell circuit breaker wiring diagram 7

Circuit breakers with a current rating of 225A or below (one set of two pairs of contacts)

The position of the circuit breaker when it is in the "closed" position

M-NZM series plastic shell circuit breaker wiring diagram 8

Circuit breakers with a current rating of 400A or higher on the shell frame (one set of four pairs of contacts)

M-NZM series plastic shell circuit breaker wiring diagram 9

Circuit breakers with a current rating of 225A or below (one set of two pairs of contacts)


External accessories of circuit breaker
1. Mechanical linkage locking mechanism for two circuit breakers
M-NZM series plastic shell circuit breaker interlock wiring

M-NZM series plastic shell circuit breaker wiring diagram 10

model
A
B
C
D
L
H
Remarks
M-NZM1-63
seventy-eight
one hundred and two
eighteen
thirteen
ninety-five
twenty-two
Used for M-NZM1-63N, H
M-NZM2-100
ninety-two
one hundred and twenty
eighteen
eleven point five
one hundred and eighteen
twenty-two
Used for M-NZM2-100N, H, L
M-NZM3-160
one hundred and seven
one hundred and thirty-five
eighteen
nine
one hundred and thirty
twenty-two
Used for M-NZM3-160N, H, L
M-NZM3-225
one hundred and seven
one hundred and thirty-five
eighteen
nine
one hundred and thirty
twenty-two
Used for M-NZM3-225N, H, L
M-NZM4-400
one hundred and fifty
one hundred and ninety
forty-two
sixteen
one hundred and seventy-five
twenty-two
Used for M-NZM4-400N, H, L
M-NZM5-630
one hundred and eighty-two
two hundred and twenty
forty-two
twelve
one hundred and ninety-eight
twenty-two
Used for M-NZM6-630N, H
M-NZM6-800
two hundred and ten
two hundred and forty
forty-two
twenty-nine point five
two hundred and thirty
twenty
Used for M-NZM-630/800H, L
M-NZM1-63/4P
one hundred and three
one hundred and thirty-two
eighteen
thirteen
one hundred and twenty-five
twenty-two
Used for M-NZM1-63 Level 4
M-NZM2-100/4P
one hundred and twenty-two
one hundred and fifty-two
eighteen
eleven point five
one hundred and fifty
twenty-two
Used for M-NZM2-100 Level 4
M-NZM3-160/4P
one hundred and forty-two
one hundred and seventy-three
eighteen
nine
one hundred and sixty-eight
twenty-two
Used for M-NZM3-160 Level 4
M-NZM3-225/4P
one hundred and forty-two
one hundred and seventy-three
eighteen
nine
one hundred and sixty-eight
twenty-two
Used for M-NZM3-225 Level 4
M-NZM4-400/4P
one hundred and ninety-eight
two hundred and forty
forty-two
sixteen
two hundred and twenty-five
twenty-two
Used for M-NZM4-400 Level 4
M-NZM5-630/4P
two hundred and forty
two hundred and eighty
forty-two
twelve
two hundred and fifty-eight
twenty-two
Used for M-NZM5-630 Level 4


M-NZM series plastic shell circuit breaker wiring diagram 11



Note: For products with M-NZM2-100 arcing distance of 50mm, L1=200mm
M-NZM series plastic shell circuit breaker appearance and installation dimensions

M-NZM series plastic shell circuit breaker

M-NZM series plastic shell circuit breaker
Product Category