| Product name: | M-NZM series plastic shell circuit breaker | ||||||
| specification: | ![]() |
||||||
| Category: | low-voltage electrical apparatus -- Molded Case Circuit Breaker | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||





| Rated current value (A) |
ten |
16,20 |
twenty-five |
thirty-two |
40,50 |
sixty-three |
eighty |
one hundred |
one hundred and twenty-five |
one hundred and sixty |
18,200,225 |
two hundred and fifty |
315,350 |
four hundred |
| Wire cross-sectional area (mm)two) |
one point five |
two point five |
four |
six |
ten |
sixteen |
twenty-five |
thirty-five |
fifty |
seventy |
ninety-five |
one hundred and twenty |
one hundred and eighty |
two hundred and forty |
|
Rated current value (A) |
Cable |
Copper bar | ||
|
Cross sectional area (mm)two) |
quantity |
Size (mm x mm) |
quantity | |
|
five hundred |
one hundred and fifty |
two |
30x5 |
two |
|
six hundred and thirty |
one hundred and eighty-five |
two |
40x5 |
two |
|
700,800 |
two hundred |
two |
40x5 |
two |


|
Rated current value (A) |
Undervoltage release power (W) | |
|
AC230V |
AC400V | |
|
M-NZM1-63 |
three point five |
three point three |
|
M-NZM2-100 |
two point six |
three point three |
|
M-NZM3-160 |
three point eight |
three point three |
|
M-NZM3-225 |
three point eight |
three point three |
|
M-NZM4-400 |
three point seven |
two point seven |
|
M-NZM5-630 |
two point three |
two point seven |
|
M-NZM6-800 |
two point five |
two point eight |
2. Split release device
Wiring diagram (dashed box shows internal attachments for production)

K: The normally closed contact of the micro switch connected in series with the coil inside the shunt release is automatically disconnected when the circuit breaker is opened and closed when it is closed.
3. Alarm contact
|
The position of the circuit breaker when it is in the "open" and "close" positions |
![]() |
|
The position of the circuit breaker when it is in "automatic trip" (alarm) mode |
|
The circuit breaker is in the "open" position |
|
Circuit breakers with a current rating of 400A or higher on the shell frame (one set of four pairs of contacts) |
|
|
Circuit breakers with a current rating of 225A or below (one set of two pairs of contacts) | |
|
The position of the circuit breaker when it is in the "closed" position |
|
Circuit breakers with a current rating of 400A or higher on the shell frame (one set of four pairs of contacts) |
|
|
Circuit breakers with a current rating of 225A or below (one set of two pairs of contacts) |


|
model |
A |
B |
C |
D |
L |
H |
Remarks | |
|
M-NZM1-63 |
seventy-eight |
one hundred and two |
eighteen |
thirteen |
ninety-five |
twenty-two |
Used for M-NZM1-63N, H | |
|
M-NZM2-100 |
ninety-two |
one hundred and twenty |
eighteen |
eleven point five |
one hundred and eighteen |
twenty-two |
Used for M-NZM2-100N, H, L | |
|
M-NZM3-160 |
one hundred and seven |
one hundred and thirty-five |
eighteen |
nine |
one hundred and thirty |
twenty-two |
Used for M-NZM3-160N, H, L | |
|
M-NZM3-225 |
one hundred and seven |
one hundred and thirty-five |
eighteen |
nine |
one hundred and thirty |
twenty-two |
Used for M-NZM3-225N, H, L | |
|
M-NZM4-400 |
one hundred and fifty |
one hundred and ninety |
forty-two |
sixteen |
one hundred and seventy-five |
twenty-two |
Used for M-NZM4-400N, H, L | |
|
M-NZM5-630 |
one hundred and eighty-two |
two hundred and twenty |
forty-two |
twelve |
one hundred and ninety-eight |
twenty-two |
Used for M-NZM6-630N, H | |
|
M-NZM6-800 |
two hundred and ten |
two hundred and forty |
forty-two |
twenty-nine point five |
two hundred and thirty |
twenty |
Used for M-NZM-630/800H, L | |
|
M-NZM1-63/4P |
one hundred and three |
one hundred and thirty-two |
eighteen |
thirteen |
one hundred and twenty-five |
twenty-two |
Used for M-NZM1-63 Level 4 | |
|
M-NZM2-100/4P |
one hundred and twenty-two |
one hundred and fifty-two |
eighteen |
eleven point five |
one hundred and fifty |
twenty-two |
Used for M-NZM2-100 Level 4 | |
|
M-NZM3-160/4P |
one hundred and forty-two |
one hundred and seventy-three |
eighteen |
nine |
one hundred and sixty-eight |
twenty-two |
Used for M-NZM3-160 Level 4 | |
|
M-NZM3-225/4P |
one hundred and forty-two |
one hundred and seventy-three |
eighteen |
nine |
one hundred and sixty-eight |
twenty-two |
Used for M-NZM3-225 Level 4 | |
|
M-NZM4-400/4P |
one hundred and ninety-eight |
two hundred and forty |
forty-two |
sixteen |
two hundred and twenty-five |
twenty-two |
Used for M-NZM4-400 Level 4 | |
|
M-NZM5-630/4P |
two hundred and forty |
two hundred and eighty |
forty-two |
twelve |
two hundred and fifty-eight |
twenty-two |
Used for M-NZM5-630 Level 4 |

Note: For products with M-NZM2-100 arcing distance of 50mm, L1=200mm
M-NZM series plastic shell circuit breaker