Scope of application
The M-NZS series plastic shell circuit breaker is one of the new types of circuit breakers developed by our company using advanced international technology. Its rated insulation voltage is 950V, suitable for AC 50Hz or (60Hz), rated working voltage of 690V and below, and rated working current of 12.5A to 630A. It is used to distribute electrical energy and is used for infrequent closing and opening under normal conditions. It also provides protection in case of overload or undervoltage of lines and equipment. Circuit breakers with rated shell level current of 400A or below can also be used for infrequent starting, operation interruption, and protection in the event of motor overload, short circuit, and undervoltage of squirrel cage motors. The product complies with GB14048.2 and IEC60947-2 standards.
Model and meaning
Note: * Circuit breakers for power distribution have no code; The circuit breaker for protecting the motor is represented by "2".
*The handle can be operated directly without a code; Electric operation function "P" represents; Rotate the handle with "Z" to indicate
*Rated short-circuit breaking capacity level: N-standard type H-high breaking type L-ultra-high breaking type
classification
1. Divided by installation method: vertical installation, horizontal installation;
2. Divided by the purpose of the circuit breaker: distribution protection type, motor protection type;
3. Divided by wiring method: front board wiring, back board wiring, plug-in wiring;
4. Divided by operation mode: direct operation of the handle, external rotation of the handle operation, and electric operation;
5. According to the type of release, there are only momentary action release (electromagnetic release), thermal+electromagnetic release (compound), and electronic release;
6. Divided by number of poles: two poles, three poles, four poles;
There are four types of neutral pole (N-pole) in a four pole circuit breaker:
Type A: The N pole does not have an overcurrent release installed, and the N pole is always connected and does not open or close together with the other three poles;
Type B: The N-pole does not have an overcurrent release installed, and the N-pole is connected and disconnected together with the other three poles;
Type C: The N-pole is equipped with an overcurrent release, and the N-pole is connected and disconnected together with the other three poles;
D-type: The N-pole is equipped with an overcurrent release, and the N-pole is always connected and does not open or close together with the other three poles;
The tripping characteristics of circuit breakers
The thermal release of the circuit breaker has inverse time limit characteristics; Electromagnetic release for instantaneous action (for power distribution) and (for motor protection)
|
Rated current of release device (A) |
Thermal release device (ambient temperature+40 ℃) |
Electromagnetic release action current (A) | |
|
1.05In (cold state) inactive time (h) |
1.30In (hot state) action time (h) | ||
|
In≤63 |
≥1 |
<1 |
10In±20% |
|
63<In≤100 |
≥2 |
<2 |
10In±20% |
|
100<In≤630 |
≥2 |
<2 |
5~10In±20% |
|
Rated current of release device (A) |
Thermal release device (with an ambient temperature of+40 ℃ for land use and+45 ℃ for marine use)
|
Electromagnetic release action current (A) | |||
|
1.0In (cold state) Non action time |
1.20In (hot state) Action Time |
1.50In (hot state) Action Time |
7.20In (cold state) Action Time | ||
|
Used for protecting electric motors 12.5≤In≤400 |
≥2 |
<2 |
≤4min |
2s<Tp≤10s |
12In±20% |
|
model |
Rated current (A) |
polar number |
Rated insulation voltage (V) |
Rated working voltage (V) |
Flying arc distance (mm) |
Ultimate short-circuit breaking capacity (kA) |
Operating short-circuit breaking capacity (kA) |
Operational performance (lifespan) times | |
|
energize |
no power | ||||||||
|
M-NZS-100N |
12.5,16,20, 25,32,40,50, 63,80,100 |
Two poles Three poles quadrupole |
nine hundred and fifty |
690 and below |
0 |
twenty-five |
twenty-five |
one thousand and five hundred |
eight thousand and five hundred |
|
M-NZS-100H |
seventy |
seventy | |||||||
|
M-NZS-100L |
one hundred and fifty |
one hundred and fifty | |||||||
|
M-NZS-160N |
16,20,25,32, 40,50,63,80, 100,125,160 |
thirty-six |
thirty-six |
one thousand
|
seven thousand | ||||
|
M-NZS-160H |
seventy |
seventy | |||||||
|
M-NZS-160L |
one hundred and fifty |
one hundred and fifty | |||||||
|
M-NZS-250N |
160,180,200, 225,250 |
thirty-six |
thirty-six |
one thousand |
seven thousand | ||||
|
M-NZS-250H |
seventy |
seventy | |||||||
|
M-NZS-250L |
one hundred and fifty |
one hundred and fifty | |||||||
|
M-NZS-400N |
200,225,250, 300,315,400 |
Three poles quadrupole |
nine hundred and fifty |
690 and below |
0 |
forty-five |
forty-five |
one thousand |
four thousand |
|
M-NZS-400H |
seventy |
seventy | |||||||
|
M-NZS-400L |
one hundred and fifty |
one hundred and fifty | |||||||
|
M-NZS-630N |
315,350,400, 500,600,630 |
forty-five |
forty-five |
one thousand |
four thousand | ||||
|
M-NZS-630H |
seventy |
seventy | |||||||
|
M-NZS-630L |
one hundred and fifty |
one hundred and fifty | |||||||
|
M-NZS-1600 |
800A 1000A 1250A 1600A |
Three poles quadrupole |
nine hundred and fifty |
690 and below |
0 |
one hundred and fifty |
one hundred and fifty |
eight hundred |
three thousand |