HomeYour location:HomeHigh voltage electrical applianceshigh-voltage circuit breakerIndoor vacuum circuit breaker → EVH6-31.5 series railway specific single pole vacuum circuit breaker
Column tabs 
Product name: EVH6-31.5 series railway specific single pole vacuum circuit breaker
specification: EVH6-31.5 series railway specific single pole vacuum circuit breaker
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Indoor vacuum circuit breaker
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


EVH6-31.5 series railway specific single pole vacuum circuit breakerDetailed product description:Column tabs
The EVH6-31.5 series railway specific single pole vacuum circuit breaker is an indoor single pole circuit breaker with a single-phase AC frequency of 50Hz and a rated voltage of 31.5kV. Specially used for railway substations and partition pavilions, for power supply, protection, and control of railway traction systems.
The circuit breaker adopts an integral layout, and the operating mechanism is an independent module with independent models. By adopting this form, the structure becomes simple and compact, and the mechanism can be individually packaged and then combined with the circuit breaker, greatly improving production efficiency and also greatly enhancing the mechanical operation reliability of the circuit breaker. The arc extinguishing chamber and operating mechanism of the circuit breaker are arranged in a front to back manner, with a reasonable structure and small volume.
The energy storage part, transmission part, buffering part, tripping part, and mechanical interlocking of the operating mechanism are all integrated into one, with only one output interface connected to the main circuit. The mechanism is composed of various forces in the mechanism, and the design will fully consider the effect of each force in the mechanism, making the arrangement of the transmission mechanism reasonable to ensure the minimum deformation of components. This not only ensures performance but also improves the reliability of the mechanism.

Technical parameters of EVH6-31.5 series railway specific single pole vacuum circuit breaker

serial number

Characteristic parameters

performance metrics

one

Rated voltage (kV)

thirty-one point five

two

Rated current (A)

two thousand and five hundred

three

Rated short-circuit breaking current (kA)

thirty-one point five

four

Rated short-circuit current breaking times (times)

thirty

five

Rated insulation level (before and after disconnection)

Rated lightning impulse withstand voltage (kV)

Alternating and relative to each other

two hundred and ten

Between fracture surfaces

two hundred and ten

Rated power frequency withstand voltage (kV 1min)

Alternating and relative to each other

one hundred and ten

Between fracture surfaces

one hundred and ten

Auxiliary circuit and control circuit

two

six

Rated dynamic stability current (kA peak)

eighty

seven

Rated thermal stability current (kA 4s)

thirty-one point five

eight

Rated short-circuit closing current (kA peak)

eighty

nine

Mechanical lifespan (times)

twenty thousand


EVH6-31.5 series railway specific single pole vacuum circuit breaker
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference