| Product name: | LW16-40.5 Type SF6 Circuit Breaker | ||||||
| specification: | ![]() |
||||||
| Category: | High voltage electrical appliances -- SF6 gas circuit breaker | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
serial number |
name |
unit |
data | |
|
one |
rated voltage |
kV |
forty point five | |
|
two |
maximum voltage |
kV |
forty point five | |
|
three |
Rated Absolute
Edge level |
Lightning impulse withstand voltage (full wave peak value) |
kV |
one hundred and eighty-five |
|
Power frequency withstand voltage (1 minute) |
kV |
ninety-five | ||
|
four |
rated current |
A |
1600 2000 | |
|
five |
mechanical life |
time |
three thousand | |
|
six |
Rated pressure of sulfur hexafluoride gas (gauge pressure at 20 ℃) |
MPa |
0.6±0.015
| |
|
seven |
Sulfur hexafluoride gas replenishment alarm pressure (gauge pressure at 20 ℃) |
MPa |
0.55±0.015 | |
|
eight |
Minimum functional pressure of sulfur hexafluoride gas |
MPa |
0.52±0.015 | |
|
nine |
Rated short-circuit breaking current |
kA |
25 31.5 | |
|
ten |
Rated short-circuit closing current (peak) |
kA |
sixty-three | |
|
eleven |
Rated short-time withstand current (thermal stability current) |
kA |
twenty-five | |
|
twelve |
Rated peak withstand current (dynamic stability current) |
kA |
sixty-three | |
|
thirteen |
Rated out of step breaking current |
kA |
six point three
| |
|
fourteen |
Accumulated breaking times under rated short-circuit breaking current |
time |
twenty-one | |
|
fifteen |
Rated short-circuit duration |
S |
four | |
|
sixteen |
Closing time (at rated operating voltage) |
S |
≤0.15 | |
|
seventeen |
Opening time (at rated operating voltage) |
S |
≤0.06 | |
|
eighteen |
Rated operating sequence |
Min-03s - Combination and Separation
-180s - combined and separated | ||
|
nineteen |
Rated opening and closing current of a single capacitor bank |
A |
four hundred | |
|
twenty |
Annual gas leakage rate |
%/Year |
≤1 | |
|
twenty-one |
Moisture content of sulfur hexafluoride gas (at 20 ℃) |
uL/L |
≤150×10ˉ6 | |
|
twenty-two |
Rated operating voltage for CT10-A spring operated mechanism |
AC/DC:220V/110V | ||
|
Energy storage motor voltage |
V |
AC/DC:110/220/380 | ||
|
twenty-three |
Weight of sulfur hexafluoride gas |
Kg |
six | |
|
twenty-four |
Weight of circuit breaker (including operating mechanism) |
kg |
one thousand | |
LW16-40.5 sulfur hexafluoride circuit breaker