HomeYour location:HomeHigh voltage electrical applianceshigh-voltage circuit breakerIndoor vacuum circuit breaker → ZN63u-15 Vacuum Circuit Breaker
Column tabs 
Product name: ZN63u-15 Vacuum Circuit Breaker
specification: ZN63u-15 Vacuum Circuit Breaker
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Indoor vacuum circuit breaker
Column tabs 
Price: factory price
Brand: 宇阳
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


ZN63u-15 Vacuum Circuit BreakerDetailed product description:Column tabs
ZN63u-15 vacuum circuit breaker

Product features

1. Mechanical durability and electrical durability
2. At rated current, the allowable number of disconnections is 10000 times
3. Under rated short-circuit current, the allowable number of disconnections is 20 times
4. Easy maintenance: only a small amount of cleaning or lubrication is needed for the operating mechanism
5. Rated current from 630A-1250A
6. The rated short-circuit breaking current ranges from 20kA to 31.5kA
7. Vertical insulation cylinder
8. Capable of defending against various environmental influences
9. Good product series and universality, easy to maintain and use for users

Technical parameters of ZN63u-15 vacuum circuit breaker

serial number
name
unit
model
ZN63u-15
one
rated voltage
kV
fifteen
two
Limi power frequency withstand voltage
Relatively speaking, time
kV
forty-two
Isolation fracture
three
Lightning impulse withstand voltage
Relatively speaking, time
kV
ninety-five
Isolation fracture
four
Rated short-circuit breaking current
kA
thirty-one point five
five
Rated short-circuit breaking current breaking times
time
twenty
six
Percentage of DC component

41%

seven
Rated dynamic stability current (peak value)
kA
one hundred
eight
3-second thermal stability current
kA
thirty-one point five
nine
Rated operating sequence
★O-0.3s-CO-180s-CO
ten
Rated cable charging breaking current
kA

25A 24 times

eleven
Rated earth fault breaking current for different phases
kA
twelve
Rated breaking current of a single capacitor bank
A
thirteen
Rated back-to-back capacitor bank breaking current
A

ZN63u-15 Vacuum Circuit Breaker
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference