Indoor vacuum circuit breakerDetailed product description:Column tabs
ZN28Z-12 series integral vacuum circuit breaker

Product features
1. Complete product range: rated current from 630A to 4000A, rated short-circuit breaking current
From 20kA to 50kA.
2. Advanced miniaturized copper chromium contact longitudinal magnetic field arc extinguishing chamber
3. Convenient and flexible structural forms and installation methods
4. Guaranteed high reliability and stability
5. Good product series and universality, easy to maintain and use for users
6. Complete product type test: rated short-circuit opening and closing current, rated dynamic stability, full capacity opening and closing
The original indicators such as the DC component value during interruption are higher than the national standards.

Technical parameters of ZN28Z-12kV indoor vacuum circuit breaker

serial number
name
unit
model
ZN28-12/20
ZN28-12/25
ZN28-12/32
ZN28-12/40
ZN28-12/50
one
rated voltage
kV
twelve
two
rated current
A

six hundred and thirty

one thousand

one thousand two hundred and fifty

one thousand

one thousand two hundred and fifty

one thousand

one thousand two hundred and fifty

two thousand

one thousand two hundred and fifty

one thousand and six hundred

two thousand

two thousand and five hundred

three thousand one hundred and fifty

four thousand
three
1-minute power frequency withstand voltage
Phase by phase ground
kV
forty-two
fracture
forty-eight
four
Lightning impulse withstand voltage Phase by phase ground
seventy-five
fracture
eighty-four
five
Rated short-circuit breaking current
kA
twenty
twenty-five
thirty-one point five
forty
fifty
six
Rated short-circuit breaking current breaking times
time
fifty
fifty
fifty
thirty
twenty
seven
Percentage of DC component
45%
45%
35%
eight
Rated dynamic stability current (peak value)
kA
fifty
sixty-three
one hundred
one hundred and thirty
one hundred and thirty
nine
4s thermal stability current
kA
twenty
twenty-five
thirty-one point five
forty
fifty
ten
Rated operating sequence
eleven
Rated out of step breaking current
kA
eight
ten
twelve point five
twelve
Rated earth fault breaking current for different phases
kA
seventeen point three
twenty-one point seven
twenty-seven point three
thirty-four point six
forty-three point three
thirteen
Rated breaking current of a single capacitor bank
A
six hundred and thirty
fourteen
Rated back-to-back capacitor bank breaking current
A
four hundred
★O-0.3s-CO-180s-CO ☆O-180s-CO-180s-CO

Indoor vacuum circuit breaker