Product name: ZW6-12 Outdoor High Voltage Vacuum Circuit Breaker
specification: ZW6-12 Outdoor High Voltage Vacuum Circuit Breaker
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Outdoor vacuum circuit breaker
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


ZW6-12 Outdoor High Voltage Vacuum Circuit BreakerDetailed product description:Column tabs
main purpose
1、 ZW6-12/630 outdoor high-voltage vacuum circuit breaker is suitable for use in three-phase AC 50HZ, rated 12KV power grids. It is used for dividing and closing load currents, overload currents, and closing and breaking currents, and can also be used as a section switch for 12KV urban or rural power grids.
2、 This product operates in a reclosing state and, when equipped with a suitable control system, can be used as a recloser or segmenter in power lines.
3、 It can be independently applied to small and medium-sized substations, with the characteristics of reducing land occupation and saving investment.
4、 Whether used in power lines or in substations, there are smart units that can be equipped with grid automation and PW to achieve local and remote control.
Usage environment
1、 Surrounding air temperature: upper limit of 40 ℃, lower limit of -40 ℃;
2、 Altitude ≤ 2000m;
3、 Wind pressure: not exceeding 700pa (equivalent to a wind speed of 34m/s);
4、 The earthquake intensity shall not exceed magnitude 8.

Technical parameters of ZW6-12 outdoor high-voltage vacuum circuit breaker

moon Technical parameter name unit Technical Specifications
16KA 20KA
one rated voltage KV twelve
two rated current A six hundred and thirty
three 1-minute power frequency withstand voltage Dry test KV forty-two
Warm test KV thirty
four Lightning impulse withstand voltage (peak value) KV seventy-five
five Rated short-circuit breaking current KA sixteen twenty
six Rated short-circuit closing current (peak) KA forty fifty
seven Rated peak withstand voltage KA forty fifty
eight 4S short-time withstand voltage KA sixteen twenty
nine Rated operating sequence Split -0.3s Split -180S Split - Split
ten Rated short-circuit current rise and break times time thirty
eleven mechanical life time ten thousand
twelve Rated voltage of energy storage motor V AC/DC 110.220
thirteen Rated operating voltage trip coil V AC/DC 110.220
closing coil
fourteen Allowable wear thickness of dynamic and static contacts mm three
fifteen Contact opening distance mm 9±1
sixteen Contact overtravel mm 3±1 3±1
seventeen Average closing speed m/s 0.6±0.2
eighteen Average opening speed m/s 1.0±0.2 1.1±0.2
nineteen Bounce time of Heku ms ≤2
twenty Three phase disconnection at different stages ms ≤2 ≤2
twenty-one Opening time (equipped with CT type spring operating mechanism) s ≤0.1
twenty-two Closing time (equipped with CT type spring operating mechanism) Maximum operating voltage s ≤0.06
Minimum operating voltage ≤0.1
twenty-three DC resistance of each phase circuit ≤200
twenty-four Center distance between phases mm one hundred and ninety-three

ZW6-12 Outdoor High Voltage Vacuum Circuit Breaker Outline and Installation Dimensional Drawing