ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker
ZW32-12 outdoor high-voltage vacuum circuit breaker (hereinafter referred to as the circuit breaker) is used in three-phase power systems with AC 50HZ and voltage of 10-12KV. It is used for breaking and closing loads, and has overload and short-circuit protection functions, meeting control and measurement requirements. It can also achieve remote control, monitoring, etc. Suitable for protection and control in power distribution systems of substations and industrial and mining enterprises, as well as frequent operation sites in rural power grids.
1.3 Model Meaning

2. Environmental conditions for use
a. Surrounding air temperature: upper limit+40 ℃, lower limit -30 ℃
b. Altitude ≤ 2000m (if altitude needs to be increased, the rated insulation level will be correspondingly increased);
c. Wind pressure: not exceeding 700pa (equivalent to a wind speed of 34m/s)
d. Amplitude: seismic intensity of 8 degrees;
e. Pollution level: Level III
f. Maximum daily temperature difference: not exceeding 25 ℃
Technical parameters of ZW32-12 outdoor high-voltage vacuum circuit breaker
| serial number |
name |
Unit |
data |
| one |
rated voltage |
KV |
twelve |
| two |
Rated insulation level |
1-minute power frequency withstand voltage |
Dry test |
forty-two |
| Warm test |
thirty-four |
| Lightning impulse withstand voltage (peak value) |
seventy-five |
| three |
rated current |
A |
630:400:200 |
| four |
Rated short-circuit breaking current |
KA |
20:16:12.5 |
| five |
Rated operating sequence |
|
Split -0.3- Split -180s - Split |
| six |
Rated short-circuit breaking current times |
time |
thirty |
| seven |
Rated short-circuit closing current (peak) |
KA |
fifty |
| eight |
Rated peak withstand current |
| nine |
Rated short-time withstand current |
twenty |
| ten |
Rated short-circuit duration |
S |
four |
| eleven |
Opening time (excitation trip) |
Maximum operating voltage |
ms |
20-45 |
| Rated operating voltage |
| Minimum operating voltage |
| twelve |
closing time |
| thirteen |
Total breaking time |
25-50 |
| ≤100 |
| fourteen |
arcing time |
≤20 |
| fifteen |
mechanical life |
time |
ten thousand |
| sixteen |
Closing power |
J |
seventy |
| seventeen |
Rated input power of energy storage motor |
W |
≤40 |
| eighteen |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220 |
| AC220 |
| nineteen |
Energy storage time at rated voltage |
S |
<10 |
| twenty |
over-current release |
rated current |
A |
five |
| Accuracy of tripping current |
% |
±10 |