HomeYour location:HomeHigh voltage electrical applianceshigh-voltage circuit breakerOutdoor vacuum circuit breaker → ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker
Column tabs 
Product name: ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker
specification: ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Outdoor vacuum circuit breaker
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


ZW32-12 Outdoor High Voltage Vacuum Circuit BreakerDetailed product description:Column tabs
ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker

ZW32-12 outdoor high-voltage vacuum circuit breaker (hereinafter referred to as the circuit breaker) is used in three-phase power systems with AC 50HZ and voltage of 10-12KV. It is used for breaking and closing loads, and has overload and short-circuit protection functions, meeting control and measurement requirements. It can also achieve remote control, monitoring, etc. Suitable for protection and control in power distribution systems of substations and industrial and mining enterprises, as well as frequent operation sites in rural power grids.

1.3 Model Meaning

ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker Model Description
2. Environmental conditions for use
a. Surrounding air temperature: upper limit+40 ℃, lower limit -30 ℃
b. Altitude ≤ 2000m (if altitude needs to be increased, the rated insulation level will be correspondingly increased);
c. Wind pressure: not exceeding 700pa (equivalent to a wind speed of 34m/s)
d. Amplitude: seismic intensity of 8 degrees;
e. Pollution level: Level III
f. Maximum daily temperature difference: not exceeding 25 ℃

Technical parameters of ZW32-12 outdoor high-voltage vacuum circuit breaker

serial number name Unit data
one rated voltage KV twelve
two Rated insulation level 1-minute power frequency withstand voltage Dry test forty-two
Warm test thirty-four
Lightning impulse withstand voltage (peak value) seventy-five
three rated current A 630:400:200
four Rated short-circuit breaking current KA 20:16:12.5
five Rated operating sequence Split -0.3- Split -180s - Split
six Rated short-circuit breaking current times time thirty
seven Rated short-circuit closing current (peak) KA fifty
eight Rated peak withstand current
nine Rated short-time withstand current twenty
ten Rated short-circuit duration S four
eleven Opening time (excitation trip) Maximum operating voltage ms 20-45
Rated operating voltage
Minimum operating voltage
twelve closing time
thirteen Total breaking time 25-50
≤100
fourteen arcing time ≤20
fifteen mechanical life time ten thousand
sixteen Closing power J seventy
seventeen Rated input power of energy storage motor W ≤40
eighteen Rated operating voltage and rated voltage of auxiliary circuit V DC220
AC220
nineteen Energy storage time at rated voltage S <10
twenty over-current release rated current A five
Accuracy of tripping current % ±10


Outline and Installation Dimensional Drawing of ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker

Outline Dimensional Drawing of ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker

ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker

ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference