HomeYour location:HomeHigh voltage electrical applianceshigh-voltage circuit breakerIndoor vacuum circuit breaker → Indoor high-voltage vacuum circuit breaker
Column tabs 
Product name: Indoor high-voltage vacuum circuit breaker
specification: Indoor high-voltage vacuum circuit breaker
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Indoor vacuum circuit breaker
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-139101609058

Email 91way@163.com
Wechat 13916500500(Wechat)


Indoor high-voltage vacuum circuit breakerDetailed product description:Column tabs
ZN40-12/630~1250-31.5, ZN41-12/1600~4000-40/50 vacuum circuit breakers are indoor high-voltage switchgear with a rated voltage of 12kV and three-phase AC 50Hz. The structure of this circuit breaker is a frame structure. The circuit breaker can be equipped with CD10 electromagnetic operating mechanism or CT8 spring operating mechanism. It can be used as the preferred circuit breaker for switchgear such as GG1A (F2) and XGN2-12.

The ZN40-12 and ZN41-12 indoor high-voltage vacuum circuit breakers have a simple structure, strong breaking capacity, long service life, complete operating functions, no explosion hazard, and easy maintenance. They are suitable for use as control or protection switches in power plants, substations, and other transmission and distribution systems, especially for breaking important loads and frequent operations.

serial number

name

ZN40-12

ZN41-12

one

Rated voltage (kV)

twelve

two

Rated current (A)

six hundred and thirty

one thousand two hundred and fifty

one thousand and six hundred

2000 2500 3150 4000

three

Rated breaking current (kA)

sixteen

twenty

twenty

thirty-one point five

thirty-one point five

40 50

four

Dynamic stability current (kA) (peak value)

forty

fifty

fifty

eighty

eighty

100 125

five

4-second thermal stability current (kA)

sixteen

twenty

twenty

thirty-one point five

thirty-one point five

40 50(3s)

six

Rated short-circuit closing current (kA) (peak value)

forty

fifty

fifty

eighty

eighty

100 125

seven

Rated short-circuit current breaking times (times)

thirty

thirty

eight

operating sequence

O-0.3s-CO-180s-CO

O-180s-CO-180s-CO

nine

Rated lightning impulse withstand voltage (kA)

75 (85 between fracture surfaces)

ten

1-minute power frequency withstand voltage (kV)

42 (48 between fracture surfaces)

eleven

Mechanical lifespan (times)

ten thousand

twelve

Rated current breaking times (times)

ten thousand


Indoor high-voltage vacuum circuit breaker
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference